SKU: ATM90-PUF13X11 Categories: , , Brand:
  • Extremely rugged, tried-and-tested absolute multiturn encoder with a resolution of up to 26 bits
  • Mechanical interface: through hollow shaft with shallow installation depth
  • Zero-set and preset functions via hardware or software
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1032655
Max. number of revolutions: 2,048
Mechanical interface: Through hollow shaft
Data protocol: Profile for encoders (07hex) – Class 2
Bus interface: RS-485
Moment of inertia of the rotor: 153 gcm²
Working temperature range: -20 °C … 80 °C
Measuring step: 0.043 °
Permissible relative humidity: 98 %
Resistance to shocks: 6 g (according to EN 60068-2-27)
Operating torque: 0.4 Ncm
Flange material: Aluminum
Bus: PROFIBUS DP
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Resolution power: 8,192 x 2,048
Bus termination: DIP switch
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz
Repeat accuracy: 0.1 °
Bearing lifetime: 3.6 x 10^9 revolutions
MTTFd: mean time to dangerous failure: 150 a (EN ISO 13849-1)
Address setting: 0 … 127, DIP-switches or protocol
Initialization time: 1,250 ms
Data transmission rate (baud rate): 9.6 kBaud / 12 MBaud / automatic detection
Max. angular acceleration: 600,000 rad/s²
Mass: 0.6 kg
Start up torque: 0.5 Ncm
Resolution: 13 bit x 11 bit
Storage temperature range: -40 °C … 125 °C, without package
Electrical interface: Bus adaptor with 3 x M14 screw fixings
Shaft diameter: 1/2 “
Operating voltage range: 10 V … 32 V
Error limits: ± 0.25 °
Shaft material: Stainless steel
Status information: LED green (operation), LED red ( bus activity)
Enclosure rating: IP 65 (according to IEC 60529), with shaft seal
Max. number of steps per revolution: 8,192
Power consumption max.: 2 W
Housing material: Die-cast aluminum
SET (electronic adjustment): Via PRESET push button or protocol

Leave a Reply