  • Measuring lengths of 1.25 m, 3 m, 5 m, and 10 m.
  • Very small dimension (55 … 190 mm)
  • Modular system: encoder type, measuring length, and interface can be selected
Contact Sales

Datasheet

Specification:

Part Number 1061027
Protocol: DeviceNet Specification Release 2.0
Working temperature range (encoder): -20 °C … +70 °C
Operating speed: 4 m/s
Resistance to shocks: 100 g, 6 ms (according to EN 60068-2-27)
Measuring wire diameter: 0.55 mm
Part number encoder: 1030018
Length of wire pulled out per revolution: 230 mm
Mass (including encoder): 840 g
Part number mechanic: 5322778
Repeatability: ≤ 0.2 mm
Working temperature range (mechanics): -30 °C … +70 °C
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Working temperature range (combination): Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik
Mounted encoder: ATM60 DeviceNet
Spring return force: Ca. 5 N … ca. 6.3 N
Number of steps per revolution: 8,192
Hysteresis: ≤ 0.4 mm
Actual length of cable extension: 3.2 m
Bus termination: Via DIP switches
Enclosure rating encoder: IP 67
SET (electronic adjustment): Via PRESET push button or protocol
Measuring wire material: Highly flexible stranded steel 1.4401 stainless steel V4A
Supply voltage: 10 V … 32 V
Linearity: ≤ ± 2 mm
Power consumption: 2 W
Address setting: 0 … 63, DIP-switches or protocol
Encoder profile: Generic Profile
Measuring range: 0 m … 3 m
Mounted mechanic: MRA-G080-103D3
Mass (measuring wire): 1.2 g/m
Connection type: Bus adaptor with cable screw fixings or connector
Initialization time: Ca. 12 s
Electrical interface: DeviceNet
Enclosure rating mechanic: IP 50
Relative humidity / Condensation: 98 % (condensation of the optical scanning not permitted)
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Resolution (wire draw + encoder): 0.03 mm
Life of wire draw mechanism: 1 million cycles
Housing material, wire draw mechanism: Plastic, Noryl
MTTFd: mean time to dangerous failure: 150 a
Encoder: Absolute encoders
Mass (mechanics): 250 g
Wire acceleration: 10 m/s?