Home
» Sick » Sick C2MT-04234BBC03DE0

Sick C2MT-04234BBC03DE0

352.58

The price is not final. Please check with the manager!
SKU: C2MT-04234BBC03DE0 Categories: , Brand:
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design – sender and receiver in a single housing
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1207852
TM (mission time): 20 a (EN ISO 13849)
PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849)
Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored
Response time: ≤ 13 ms
External device monitoring (delivery status): Deactivated
Conductor cross-section: 0.34 mm?
Protective field height: 420 mm
Cascaded:
Safe SICK device communication via EFI/SDL:
Safety integrity level: SIL1 (IEC 61508)
SILCL1 (EN 62061)
Permitted cable length: ≤ 20 m
Weight: 155 g
Maximum demand rate: 34 /min (EN ISO 13849)
Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics!
Beam coding: +
Typical range: 0 m … 8 m
Enclosure rating: IP 65 (EN 60529)
Synchronization: Optical, without separate synchronization
Display elements: LEDs
Cable length: 350 mm
Type: Type 2 (IEC 61496)
Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Housing material: Aluminum alloy ALMGSI 0.5
Vibration resistance: 5 g, 10 Hz … 55 Hz (EN 60068-2-6)
Shock resistance: 10 g, 16 ms (EN 60068-2-27)
Scanning range: 0 m … 6 m
Switching voltage LOW: 2 V DC
Storage temperature: -25 °C … +70 °C
Power consumption: ≤ 3 A
Supply voltage: 24 V DC (19.2 V DC … 28.8 V DC)
Switching current: 300 mA
Connection type: Male connector M12, 5-pin
Air humidity: 15 % … 95 %, non-condensing
Protection class: III (EN 61140)
Category: Category 2 (EN ISO 13849)
Ripple: ≤ 10 %
External device monitoring (EDM): +
Safe state in the event of a fault: At least one OSSD is in the OFF state.
Switching voltage HIGH: 24 V DC (VS – 2.25 V DC … VS)
Resolution: 34 mm
Housing cross-section (incl. system connection): 15 mm x 32 mm
Configuration method: Hard wired
Restart interlock (delivery status): Deactivated
Restart interlock: +
Test rate (internal test): 58 /s
Ambient operating temperature: -20 °C … +55 °C