Home
» Sick » Sick C2MT-09014BBC03FE0

Sick C2MT-09014BBC03FE0

659.77

The price is not final. Please check with the manager!
SKU: C2MT-09014BBC03FE0 Categories: , Brand:
  • Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design – sender and receiver in a single housing
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1207816
Ripple: ≤ 10 %
Housing cross-section (incl. system connection): 15 mm x 32 mm
Power consumption: ≤ 3 A
Enclosure rating: IP 65 (EN 60529)
Conductor cross-section: 0.34 mm²
Permitted cable length: ≤ 20 m
Housing material: Aluminum alloy ALMGSI 0.5
Synchronization: Optical, without separate synchronization
Vibration resistance: 5 g, 10 Hz … 55 Hz (EN 60068-2-6)
Safety integrity level: SIL1 (IEC 61508)
SILCL1 (EN 62061)
Ambient operating temperature: -20 °C … +55 °C
Display elements: LEDs
Type: Type 2 (IEC 61496)
Supply voltage: 24 V DC (19.2 V DC … 28.8 V DC)
Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Air humidity: 15 % … 95 %, non-condensing
Beam coding: +
Configuration method: Hard wired
TM (mission time): 20 a (EN ISO 13849)
Connection type: Male connector M12, 5-pin
Weight: 320 g
Restart interlock: +
Test rate (internal test): 58 /s
Protective field height: 900 mm
External device monitoring (delivery status): Deactivated
Switching voltage LOW: 2 V DC
Storage temperature: -25 °C … +70 °C
Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics!
Safe state in the event of a fault: At least one OSSD is in the OFF state.
Cascaded:
Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored
Automatic beam coding: +
Safe SICK device communication via EFI/SDL:
Resolution: 14 mm
Category: Category 2 (EN ISO 13849)
Typical range: 0 m … 8 m
Response time: ≤ 17 ms
Switching voltage HIGH: 24 V DC (VS – 2.25 V DC … VS)
Scanning range: 0 m … 6 m
Shock resistance: 10 g, 16 ms (EN 60068-2-27)
External device monitoring (EDM): +
Maximum demand rate: 34 /min (EN ISO 13849)
Cable length: 700 mm
Protection class: III (EN 61140)
Restart interlock (delivery status): Deactivated
PFHd: Standalone system: 2.4  1E-08 (EN ISO 13849)
Switching current: 300 mA