  • Type 4 (IEC 61496), SIL3 (IEC 61508), PL e (EN ISO 13849)
  • Compact cross section (15 mm x 32 mm) with no dead zones
  • Cascadable twin stick design – sender and receiver in a single housing
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1207300
Switching voltage HIGH: 24 V DC (VS – 2.25 V DC … VS)
Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET
Switching current: 300 mA
Display elements: LEDs
Cable length: 160 mm
Beam coding: +
Power consumption: ≤ 3 A
Switching voltage LOW: 2 V DC
Performance level: PL e (EN ISO 13849)
TM (mission time): 20 a (EN ISO 13849)
Connection type extension connection: Female connector M12, 5-pin
Synchronization: Optical, without separate synchronization
Housing material: Aluminum alloy ALMGSI 0.5
Safe SICK device communication via EFI/SDL:
Ambient operating temperature: -20 °C … +55 °C
Safe state in the event of a fault: At least one OSSD is in the OFF state.
External device monitoring (delivery status): Deactivated
Air humidity: 15 % … 95 %, non-condensing
Shock resistance: 10 g, 16 ms (EN 60068-2-27)
Vibration resistance: 5 g, 10 Hz … 55 Hz (EN 60068-2-6)
Type: Type 4 (IEC 61496)
Automatic beam coding: +
Enclosure rating: IP 65 (EN 60529)
Scanning range: 0 m … 4 m
Category: Category 4 (EN ISO 13849)
Storage temperature: -25 °C … +70 °C
Protection class: III (EN 61140)
Resolution: 34 mm
Connection type: Male connector M12, 5-pin
Ripple: ≤ 10 %
Conductor cross-section: 0.34 mm?
Housing cross-section (incl. system connection): 15 mm x 32 mm
Supply voltage: 24 V DC (19.2 V DC … 28.8 V DC)
Weight: 50 g
Protective field height: 120 mm
Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored
Safety integrity level: SIL3 (IEC 61508)
SILCL3 (EN 62061)
Restart interlock (delivery status): Deactivated
Response time: ≤ 13 ms
Typical range: 0 m … 5 m
Configuration method: Hard wired
Cascaded: +
External device monitoring (EDM): +
PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849)
Restart interlock: +
Permitted cable length: ≤ 20 m