Part Number 1041786
Protocol (CAN bus): CANopen, CSN (SICK CAN Sensor Network)
No. of codes per reading interval: 1 … 50 (auto-discriminating)
Note on use: For Ethernet connection please use an Ethernet version of CLV6xx
Acoustic indicators: Beeper/buzzer (can be switched off, can be allocated as a result indication function)
Remark (DeviceNet): Optional via external connection module (CDM + CMF)
Ambient operating temperature: 0 °C … +40 °C
Scanner design: Raster scanner
Print ratio: 2:1 … 3:1
Vibration resistance: EN 60068-2-6 (1995)
Data transmission rate (Serial (RS-232, RS-422/485)): 2,400 Baud … 115 kBaud, AUX: 57.6 kBaud
Reading pulse: Auto pulse, CAN, Non-powered, Switching inputs, Serial interface
Code resolution: 0.35 mm … 1 mm
Switching inputs: 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional parameter storage CMC600 in CDB620/CDM420)
Bar code print contrast (PCS): ≥ 60 %
MTBF: 40,000 h
Raster height, number of lines, at distance: 15 mm, 8, 200 mm
No. of multiple readings: 1 … 99
Remark (Serial (RS-232, RS-422/485)): AUX (only RS-232)
Housing: Die-cast aluminum
Housing color: Light blue (RAL 5012)
Configuration software: SOPAS ET
Version: Long Range
Function (Serial (RS-232, RS-422/485)): Host, AUX
Laser class: 2 (EN 60825-1 (A2:2001-03))
Focus: Fixed focus
DeviceNet: +
Weight: 225 g, with connecting cable
Light source: Visible red light (655 nm)
Ambient light safety: 2,000 lx, on bar code
Scanning frequency: 400 Hz … 1,200 Hz
Ethernet:
No. of characters per reading interval: 1,500, 500 (for multiplexer function in CAN operation)
Permissible relative humidity: 90 %, non-condensing
Protection class: III (VDE 0106/IEC 1010-1)
Shock resistance: EN 60068-2-27 (1993)
Operating voltage: 10 V DC … 30 V DC
Remark (PROFIBUS DP): Optional via external connection module (CDF600-2)
Dimensions: 61 mm x 66 mm x 38 mm
Field of view: ≤ 50 °
Reading field: Front
Front screen: Glass
Power consumption: 4.5 W
Reading distance: 60 mm … 730 mm
CAN bus: +
Function (CAN bus): SICK CAN sensor network (Master/Slave, Multiplexer/Server)
Serial (RS-232, RS-422/485): +
Switching outputs: 4 (“Result 1”, “Result 2”, 2 outputs via optional parameter storage CMC600 in CDB620/CDM420)
Optical indicators: 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX)
Enclosure rating: IP 65 (DIN 40 050)
No. of codes per scan: 1 … 20 (Standard decoder), 1 … 6 (SMART620)
Bar code types: Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, GS1 DataBar, GS1-128 / EAN 128, MSI/Plessey, Pharmacode, Telepen, UPC / GTIN / EAN
Protocol (Ethernet): PROFINET Dual Port (optional via external connection module CDF600-2), EtherCAT (optional via external connection module CDF600)
Data transmission rate (CAN bus): 20 kbit/s … 1 Mbit/s
Electromagnetic compatibility (EMC): EN 61000-6-3 (2001-10) / EN 61000-6-2:2005
PROFIBUS DP: +
Electrical connection: 1 x 15-pin D-Sub HD male connector (0.9 m)
Connection type: Cable
Storage temperature: -20 °C … +70 °C