Datasheet
Specification:
| Part Number | 1056611 |
| Data transmission rate (Serial (RS-232, RS-422/485)): | 300 Baud … 500 kBaud, AUX: 57.6 kBaud (RS-232) |
| Heating: | With heating |
| Field of view: | ≤ 60 ° |
| Housing: | Die-cast aluminum |
| Ethernet: | + |
| Configuration software: | SOPAS ET |
| Data transmission rate (CAN bus): | 20 kbit/s … 1 Mbit/s |
| Function (CAN bus): | SICK CAN sensor network (Master/Slave, Multiplexer/Server) |
| Shock resistance: | EN 60068-2-27 (2009-05) |
| CAN bus: | + |
| Power consumption: | 80 W |
| Ambient light safety: | 2,000 lx, on bar code |
| Remark (PROFIBUS DP): | Optional via external connection module (CDF600-2) |
| Electrical connection: | Depending on the cloning plug used |
| Optical indicators: | 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate percentage (10 LEDs)) |
| Scanning frequency: | 400 Hz … 1,200 Hz |
| Focus: | Auto focus (alternative: dynamic focus control) |
| Storage temperature: | -20 °C … +70 °C |
| Switching outputs: | 4 (“Result 1” … “Result 4”) |
| Serial (RS-232, RS-422/485): | + |
| Enclosure rating: | IP 65 (IEC 60529 (1989-11)) |
| Print ratio: | 2:1 … 3:1 |
| MTBF: | 100,000 h |
| Operating voltage: | 21.6 V DC … 28.8 V DC |
| Protocol (CAN bus): | CSN (SICK CAN Sensor Network) |
| Function (Serial (RS-232, RS-422/485)): | Host, AUX (only RS-232) |
| Remark (Serial (RS-232, RS-422/485)): | Only with cloning plug D-Sub and Ethernet |
| DeviceNet: | + |
| Code resolution: | 0.17 mm … 0.4 mm |
| Protocol (Ethernet): | TCP/IP, EtherNet/IP, PROFINET (optional via external connection module CDF600-2), PROFINET Dual Port (optional via external connection module CDF600-2) |
| No. of codes per reading interval: | 1 … 50 (auto-discriminating) |
| Oscillation frequency: | 0.5 Hz … 4 Hz |
| Focus trigger source: | Data interface, Switching inputs |
| No. of codes per scan: | 1 … 20 (Standard decoder), 1 … 6 (SMART decoder) |
| Remark (Ethernet): | Only with cloning plug I/O, CAN IN/OUT or CAN Redundant |
| Version: | High Density |
| Housing color: | Light blue (RAL 5012) |
| Switching inputs: | 6 (“Sensor 1” … “Sensor 6”) |
| Connection type: | Depending on the cloning plug used |
| Focus adjustment time: | ≤ 20 ms |
| Reading pulse: | Auto pulse, CAN, Switching inputs, Serial interface |
| Remark (DeviceNet): | Optional via external connection module (CDM + CMF) |
| Bar code types: | Interleaved 2 of 5, All current code types, Codabar, Code 128, Code 39, Code 93, GS1-128 / EAN 128, UPC / GTIN / EAN |
| No. of multiple readings: | 1 … 100 |
| Light source: | Visible red light (660 nm) |
| No. of characters per reading interval: | 5,000 |
| Reading field: | Oscillating mirror |
| Protection class: | III (EN 60950-1 (2011-01)) |
| Reading distance: | 400 mm … 1,500 mm |
| Dimensions: | 182 mm x 128 mm x 97 mm |
| Control elements: | 2 buttons |
| Laser class: | 2 (IEC 60825-1 (2007-3)) |
| Function (Ethernet): | Host, AUX |
| Parameter storage: | Integrated in cloning plug |
| Oscillating mirror functions: | Fixed (adjustable position), One shot, Oscillating (variable or fixed amplitude) |
| Permissible relative humidity: | 90 %, non-condensing |
| Front screen: | Glass |
| Weight: | 2,200 g |
| Angle of deflection: | -20 ° … 20 ° (can be adjusted via software) |
| No. of distance configurations: | 8 |
| Scanner design: | Line scanner |
| Vibration resistance: | EN 60068-2-6 (2008-02) |
| Ambient operating temperature: | -35 °C … +40 °C |
| Data transmission rate (Ethernet): | 10/100 Mbit |
| PROFIBUS DP: | + |