  • Compact installation depth
  • High resolution up to 16 bits
  • Optionally programmable: Output voltage, zero pulse position, zero pulse width and number of pulses
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1052505
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Electrical interface: 10 V … 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m
Mechanical interface: Blind hollow shaft
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Shaft diameter: 10 mm
Working temperature range: 0 °C … +85 °C
Max. angular acceleration: 500,000 rad/s?
Bearing lifetime: 3.6 x 10^10 revolutions
Maximum operating speed: 6,000 /min
Initialization time: 40 ms
Pulses per revolution: 1,024
MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)
Shaft material: Metal
Measuring step deviation: ± 0.2 °
Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Measuring step: 90 ° / electronically/number of lines
Connection type: Cable, 8-wire, universal, 5 m
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Maximum output frequency: 300 kHz
Error limits: ± 0.3 °
Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm
Operating torque: 0.6 Ncm (+20 °C)
Power consumption: 0.5 W (without load)
Storage temperature range: -40 °C … +100 °C, without package
Load current max.: 30 mA
Reference signal, position: 90 °, electronically, gated with A and B
Reference signal, number: 1
Operating voltage range: 10 V … 32 V
Start up torque: 0.8 Ncm (+20 °C)
Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm
Mass: 0.2 kg
Moment of inertia of the rotor: 40 gcm?
Resistance to shocks: 50 g (according to EN 60068-2-27)