Specification:
Part Number | 1037351 |
Permissible relative humidity: | 90 % (condensation of the optical scanning not permitted) |
Resistance to shocks: | 50 g (according to EN 60068-2-27) |
Enclosure rating: | IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side |
Reference signal, position: | 90 °, electronically, gated with A and B |
Working temperature range: | 0 °C … +85 °C |
Connection type: | Cable, 8-wire, universal, 3 m |
Operating torque: | 0.3 Ncm (+20 °C) |
Storage temperature range: | -40 °C … +100 °C, without package |
Shaft diameter: | 10 mm x 19 mm |
Pulses per revolution: | 2,048 |
Mass: | 0.3 kg |
Max. angular acceleration: | 500,000 rad/s? |
EMC: | (according to EN 61000-6-2 and EN 61000-6-3) |
Reference signal, number: | 1 |
Initialization time: | 40 ms |
Electrical interface: | 4.5 V … 5.5 V, TTL/RS422, Cable, 8-pin, universal, 3 m |
Maximum output frequency: | 300 kHz |
Error limits: | ± 0.3 ° |
Measuring step: | 90 ° / electronically/number of lines |
Mechanical interface: | Solid shaft, Face mount flange |
Bearing lifetime: | 3.6 x 10^10 revolutions |
Maximum operating speed: | 10,000 /min |
Permissible shaft loading radial/axial: | 40 N (axial), 80 N (radial) |
Resistance to vibration: | 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6) |
Load current max.: | 30 mA |
Start up torque: | 0.5 Ncm (+20 °C) |
MTTFd: mean time to dangerous failure: | 300 a (EN ISO 13849-1) |
Moment of inertia of the rotor: | 6.2 gcm? |
Operating voltage range: | 4.5 V … 5.5 V |