  • Compact installation depth
  • High resolution up to 16 bits
  • Optionally programmable: Output voltage, zero pulse position, zero pulse width and number of pulses
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1036510
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Operating torque: 0.6 Ncm (+20 °C)
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Load current max.: 30 mA
Shaft material: Metal
Operating voltage range: 4.5 V … 5.5 V
Error limits: ± 0.3 °
Maximum output frequency: 300 kHz
Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm
Moment of inertia of the rotor: 40 gcm?
Bearing lifetime: 3.6 x 10^10 revolutions
Measuring step: 90 ° / electronically/number of lines
Maximum operating speed: 9,000 /min
Pulses per revolution: 1,024
Working temperature range: 0 °C … +85 °C
Reference signal, number: 1
Start up torque: 0.8 Ncm (+20 °C)
Mass: 0.2 kg
Max. angular acceleration: 500,000 rad/s?
Electrical interface: 4.5 V … 5.5 V, TTL/RS422, Connector M12, 8-pin, radial
Measuring step deviation: ± 0.2 °
Resistance to shocks: 50 g (according to EN 60068-2-27)
MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)
Storage temperature range: -40 °C … +100 °C, without package
Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm
Connection type: Male connector M12, 8-pin, radial
Shaft diameter: 12 mm
Initialization time: 40 ms
Reference signal, position: 90 °, electronically, gated with A and B
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Mechanical interface: Through hollow shaft
Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side