Home
» Sick » Sick DFS60E-TGEM01024

Sick DFS60E-TGEM01024

259.96

The price is not final. Please check with the manager!
SKU: DFS60E-TGEM01024 Categories: , , Brand:
  • Compact installation depth
  • High resolution up to 16 bits
  • Optionally programmable: Output voltage, zero pulse position, zero pulse width and number of pulses
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1052430
Load current max.: 30 mA
Initialization time: 40 ms
Measuring step deviation: ± 0.2 °
Working temperature range: 0 °C … +85 °C
Mechanical interface: Through hollow shaft
Electrical interface: 10 V … 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m
Reference signal, number: 1
Power consumption: 0.5 W (without load)
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Mass: 0.2 kg
Shaft material: Metal
Pulses per revolution: 1,024
Moment of inertia of the rotor: 40 gcm?
Resistance to shocks: 50 g (according to EN 60068-2-27)
Operating torque: 0.6 Ncm (+20 °C)
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Shaft diameter: 14 mm
Max. angular acceleration: 500,000 rad/s?
Maximum output frequency: 300 kHz
Maximum operating speed: 9,000 /min
Error limits: ± 0.3 °
Storage temperature range: -40 °C … +100 °C, without package
Measuring step: 90 ° / electronically/number of lines
Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm
Connection type: Cable, 8-wire, universal, 5 m
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Start up torque: 0.8 Ncm (+20 °C)
Operating voltage range: 10 V … 32 V
Reference signal, position: 90 °, electronically, gated with A and B
Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm
Bearing lifetime: 3.6 x 10^10 revolutions
Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)