Specification:

Part Number 1037811
Storage temperature range: -40 °C … +100 °C, without package
Shaft material: Metal
Initialization time: 40 ms
Max. angular acceleration: 500,000 rad/s?
Mass: 0.2 kg
MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1)
Maximum operating speed: 9,000 /min
Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side
Operating voltage range: 10 V … 32 V
Shaft diameter: 15 mm
Pulses per revolution: 1,000
Operating torque: 0.6 Ncm (+20 °C)
Working temperature range: 0 °C … +85 °C
Start up torque: 0.8 Ncm (+20 °C)
Resistance to shocks: 50 g (according to EN 60068-2-27)
Reference signal, number: 1
Measuring step deviation: ± 0.2 °
Power consumption: 0.5 W (without load)
Mechanical interface: Through hollow shaft
Reference signal, position: 90 °, electronically, gated with A and B
Load current max.: 30 mA
Permissible relative humidity: 90 % (condensation of the optical scanning not permitted)
Bearing lifetime: 3.6 x 10^10 revolutions
EMC: (according to EN 61000-6-2 and EN 61000-6-3)
Connection type: Connector M23, 12-pin, radial
Maximum output frequency: 300 kHz
Resistance to vibration: 20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)
Moment of inertia of the rotor: 40 gcm?
Measuring step: 90 ° / electronically/number of lines
Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm
Error limits: ± 0.3 °
Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm
Electrical interface: 10 V … 32 V, TTL/RS422, Connector M23, 12-pin, radial