Datasheet
Specification:
| Part Number | 1051334 |
| Initialization time: | 30 ms |
| Pulses per revolution: | 65,536 |
| MTTFd: mean time to dangerous failure: | 300 a (EN ISO 13849-1) |
| Protection class standard: | IEC 60529 |
| Connection type: | Cable, universal, 3 m |
| Preload spring arm: | 20 mm |
| Enclosure rating: | IP 65 |
| EMC: | EN 61000-6-2, EN 61000-6-3 |
| Air humidity: | 90 % |
| Mechanical interface: | 2 measuring wheels, ‘O’ ring surface |
| Maximum output frequency: | 820 kHz |
| Maximum operating speed: | 3,000 U/min |
| Spring deflection spring arm: | 40 mm |
| Reference signal, number: | 1 |
| Output current: | 30 mA |
| Resistance to shocks: | 70 g, 6 ms (EN 60068-2-27) |
| Working temperature range: | -20 °C … +100 °C |
| Reference signal, position: | 90 °, electronically, gated with A and B |
| Supply voltage: | 4.5 V … 32 V |
| Error limits ‘O’ ring surface: | ± 0.03 mm |
| Measuring step deviation: | ± 0.002 ° |
| Mass: | 0.5 kg |
| Resistance to vibration: | 30 g, 2,000 Hz … 10 Hz (EN 60068-2-6) |
| Storage temperature range: | -40 °C … +100 °C, without package |
| Electrical interface: | 4.5 V … 32 V, TTL/HTL programmable, Cable, universal, 3 m |
| Bearing lifetime: | 3 x 10^9 revolutions |