SKU: DL100-11HA2103 Categories: , , Brand:
  • Measuring range up to 220 m (dependent on type)
  • Numerous fieldbus interfaces
  • Pre-failure notification and diagnostic data available
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1059962
Typ. light spot size (distance): 5 mm (+ 2 mm x distance in m)
Temperature drift: Typ. 0.1 mm/K
Enclosure rating: IP 65
Max. movement speed: 30 m/s
Mechanical load: Noise: EN 600 68-2-64
Shock: EN 600 68-2-27
Sine: EN 600 68-2-6
Output time: Synchronous to PLC request (dependent on interfaces)
Internal measurement cycle: 1 ms
Weight : Ca. 800 g … 1,600 g
Modulation frequency: Fix
Resolution: 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
Initialization time : Typ. 1.5 s
Supply voltage Vs: DC 18 V … 30 V, limit values
Effect of air pressure: 0.3 ppm/hPa
Housing material: Aluminum/zinc die-cast
Electromagnetic compatibility (EMC) : EN 61000-6-2 / EN 61000-6-4
Indication: 6 digit 5 x 7 dot matrix display, LEDs
Laser class: 2 (EN 60825-1 / CDRH)
Connection type: Male connector, M12, SPEEDCON™ compatible
Power consumption: At 24 V DC < 1,000 mA
Multifunctional input (MF) : 1 x MF1
Output current IA : ≤ 100 mA
Ambient temperature : Operation with cooling case: -40 … +75 °C
Storage: -40 … +75 °C
Operation with heating: -40 … +55 °C
Protection class: III
Switching output : B (push/pull)
MF1, MF2
Light source : Laser, red
Measuring range: 0.15 m … 60 m, On reflective tape “Diamond Grade”
Repeatability : 1.5 mm (at dead time 10 ms), 0.75 mm (at dead time 30 ms)
Effect of air temperature: 1 ppm/K
Accuracy : ± 3 mm
Data interface: RS-422
Ripple : 5 Vpp