Part Number 1060048
Repeatability : 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms)
Temperature drift: Typ. 0.1 mm/K
Electromagnetic compatibility (EMC) : EN 61000-6-2 / EN 61000-6-4
Housing material: Aluminum/zinc die-cast
Resolution: 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
Laser class: 2 (EN 60825-1 / CDRH)
Multifunctional input (MF) : 1 x MF1
Output current IA : ≤ 100 mA
Modulation frequency: Fix
Weight : Ca. 800 g … 1,600 g
Indication: 6 digit 5 x 7 dot matrix display, LEDs
Effect of air pressure: 0.3 ppm/hPa
Supply voltage Vs: DC 18 V … 30 V, limit values
Connection type: Male connector, M12, SPEEDCON™ compatible
Typ. light spot size (distance): 5 mm (+ 2 mm x distance in m)
Mechanical load: Noise: EN 600 68-2-64
Shock: EN 600 68-2-27
Sine: EN 600 68-2-6
Switching output : B (push/pull)
MF1, MF2
Enclosure rating: IP 65
Initialization time : Typ. 1.5 s
Data interface: PROFINET
Accuracy : ± 4 mm
Measuring range: 0.15 m … 130 m, On reflective tape “Diamond Grade”
Power consumption: At 24 V DC < 1,000 mA
Light source : Laser, red
Output time: Synchronous to PLC request (dependent on interfaces)
Max. movement speed: 30 m/s
Ambient temperature : Operation with cooling case: -40 … +75 °C
Storage: -40 … +75 °C
Operation with heating: -40 … +55 °C
Ripple : 5 Vpp
Effect of air temperature: 1 ppm/K
Internal measurement cycle: 1 ms
Protection class: III