Datasheet
Specification:
| Part Number | 1047617 |
| Resolution: | 1 mm |
| Additional function: | Switch-off display Set moving average: fast/slow Set hysteresis Switching mode: distance to object (DtO) Lock user interface Reset to factory default Teach-in, scaling and inversion of analog output Teach-in, scaling and inversion of switching output Multifunctional input: laser off / external teach / deactivated |
| Typ. light spot size (distance): | 15 mm x 15 mm (10 m) |
| Vibration resistance: | EN 60068-2-6 / EN 60068-2-64 |
| Repeatability : | 5 mm / 2.5 mm |
| Power consumption : | ≤ 2.1 W |
| Connection type: | Male connector, M12, 5-pin |
| Enclosure rating: | IP 65 |
| Light source: | Laser, red |
| Warm-up time: | ≤ 15 min |
| Multifunctional input (MF) : | 1 x |
| Max. rel. humidity (not condensing): | ≤ 95 % |
| Hysteresis: | 10 mm … 1,000 mm |
| Shock resistance: | EN 60068-2-27 |
| Housing material: | Die-cast zinc housing (ZNAL4CU1) acrylic glass (PMMA) |
| Ambient temperature: | Operation: -30 … +65 °C, Storage: -40 … +75 °C |
| Resolution analog output: | 16 bit |
| Output time : | ≥ 4 ms |
| Switching output : | 1 x NPN (100 mA) |
| Laser class: | 1 (EN 60825-1) |
| Measuring range: | 200 mm … 10,000 mm, 90 % remision 200 mm … 2,500 mm, 6 % remission 200 mm … 5,000 mm, 18 % remission |
| Accuracy : | ± 10 mm |
| Analog output: | 1 x 0 V … 10 V (≥ 5 k&;937;) |
| Response time : | 20 ms / 30 ms |
| Typ. ambient light safety: | 40 klx |
| Initialization time: | ≤ 250 ms |
| Laser service life (MTTF at 25 °C): | 100,000 h |
| Indication: | 2 x LED, LC display |
| Protection class: | III |
| Supply voltage Vs : | DC 15 V … 30 V |
| Weight: | 200 g |
| Ripple : | ≤ 5 Vpp |