SKU: KHK53-AXT00107 Categories: , , Brand:
  • Non-contact length measurement – maintenance-free, rugged, long lifetime
  • High reproducibility (0.3 mm / 1 mm), high system resolution (0.1 mm)
  • SSI and PROFIBUS interfaces
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1030060
EMC: (according to EN 61000-6-2 and EN 61000-6-4)
Working temperature range: -20 °C … +60 °C
Resistance to vibration: 10 g, 20 Hz … 250 Hz (EN 60068-2-6)
Piston speed: 6.6 m/s
Storage temperature range: -40 °C … +85 °C
Enclosure rating: IP 66 (IEC 60529)
Measurement accuracy: ± 1000 + ME (Tu-25° C) Tk µm
Interface for parametrization: Data format: 1 start bit, 8 data bits, 1 stop bit, no parity, Data protocol: ASCII, Baud rate 9600 RS-422, RS-422, Four wire transmission, asynchrony, full duplex
Supply voltage: 10 V … 32 V
Power consumption: 250 mA
Electrical interface: SSI
Interface signals: Digital, serial
Repeat accuracy: 0.3 mm
Resolution: 0.1 mm
MTTFd: mean time to dangerous failure: 40 a (EN ISO 13849)
Position tolerance: ± 10 mm
Resistance to shocks: 30 g, 10 ms (DIN EN 60 068-2-27)
Mass: 2.7 kg
Initialization time: 2 s
Connection type: Cable, 5 m
Measuring range: 107 m
Standard (default setting SSI standard): RS-422 off
Material: AlMgSiPbF28
Position forming time: 0.8 ms
Measuring length: 0 m … 107 m
Data format: SSI 24 bits format