Specification:
| Part Number | 1036165 |
| Material: | AlMgSiPbF28 |
| Mass: | 3.6 kg |
| Storage temperature range: | -40 °C … +85 °C |
| Piston speed: | 6.6 m/s |
| Data protocol: | Profibus DP basic functions, Profile for encoders (07hex) – Class 2 |
| Enclosure rating: | IP 67 (IEC 60529), with mating connector inserted |
| Resistance to shocks: | 30 g, 10 ms (DIN EN 60 068-2-27) |
| Connection type: | 3 x connector M12 |
| Resistance to vibration: | 10 g, 20 Hz … 250 Hz (EN 60068-2-6) |
| Bus interface: | RS-485 |
| Measuring range: | 354 m |
| Electrical interface: | PROFIBUS DP |
| Measuring length: | 0 m … 354 m |
| Address setting: | 0 … 127, Hex switches or Protocol |
| SET (electronic adjustment): | Via protocol |
| Bus termination: | Via external switches |
| Resolution: | 0.1 mm |
| Repeat accuracy: | 0.3 mm |
| EMC: | (according to EN 61000-6-2 and EN 61000-6-4) |
| MTTFd: mean time to dangerous failure: | 28 a (EN ISO 13849) |
| Supply voltage: | 10 V … 32 V |
| Initialization time: | 2 s |
| Measurement accuracy: | ± 1000 + ME (Tu-25° C) Tk µm |
| Status information: | Operation (LED green), Bus aktivity (LED red) |
| Working temperature range: | -20 °C … +60 °C |
| Position forming time: | 1.1 ms |
| Position tolerance: | ± 10 mm |
| Power consumption: | 2.5 W |