Specification:

Part Number 1052069
Upper signal level: 20 mA … 20.5 mA
Accuracy of sensor element: ± 5 mm
Process pressure: -1 bar … 16 bar
Output current: < 100 mA
EMC: EN 61326-1:2006, 2004/108/EG
Lower signal level: 3.8 mA … 4 mA
Resolution: < 2 mm
Temperature drift: < 0.1 mm/K
Inductive load: < 1 H
Probe length: 400 mm
Medium: Fluids
Supply voltage: 12 V DC … 30 V DC
Repeatability: ≤ 2 mm
Measurement: Switch, Continuous
Conductivity: No limitation
Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK
IO-Link: +
Ambient temperature operation: -20 °C … +60 °C
Ambient storage temperature: -40 °C … +80 °C
Interference emission: EN 61000-6-4:2007
Signal voltage HIGH: Vs – 2 V
Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
Power consumption: ≤ 75 mA at 24 V DC without output load
EHEDG approval: +
3-A:
Inactive area at process connector: 25 mm
MTTF: 194.3 a (EN ISO 13849-1)
Protection class: III
Capacitive load: 100 nF
Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe
Housing material: 303
Output load: 0 V … 10 V > 750 Ohm at Uv >= 14 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V
Hysteresis: Min. 2 mm, free adjustable
UL approval: +
Process connection: G ¾ A
Initialization time: ≤ 2 s
Single- and continuous shock: EN 60068-2-27
GOST approval: +
Housing design: With PMMA viewing window
Response time: < 400 ms
RoHS certificate: +
Interference resistance: EN 61000-6-2:2005
Signal voltage LOW: ≤ 2 V
Process temperature: -20 °C … +150 °C
Inactive area at probe end: 10 mm
Max.probe load: 6 Nm
Connection type: Round connector M12 x 1, 5-pin