SKU: LFP0500-N1DMB Categories: , , Brand:
  • Level monitoring in hygienic applications
  • Manually cutable monoprobe up to 4,000 mm long with Ra lessthan 0.8 µm
  • Process temperature up to 180 °C, process pressure up to 16 bar
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1071140
Length coaxial cable: 3.3 m, FEP
Output load: 0 V … 10 V > 750 Ohm at Uv >= 14 V, 4 mA … 20 mA < 400 Ohm at Uv > 12 V, 4 mA … 20 mA < 500 Ohm at Uv > 13,5 V
Process temperature: -20 °C … +180 °C
IO-Link: +
Power consumption: ≤ 75 mA at 24 V DC without output load
Hysteresis: Min. 2 mm, free adjustable
EHEDG approval: +
Interference emission: EN 61000-6-4:2007
RoHS certificate: +
Medium: Fluids
Signal voltage HIGH: Vs – 2 V
EMC: EN 61326-1:2006, 2004/108/EG
Process connection: ?” NPT
Ambient temperature coaxial cable: -20 °C … +60 °C
Response time: < 400 ms
Probe length: 500 mm
Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe
Ambient storage temperature: -40 °C … +80 °C
Housing material: 303
Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK
Conductivity: No limitation
Supply voltage: 12 V DC … 30 V DC
Ambient temperature operation: -20 °C … +60 °C
Inactive area at probe end: 10 mm
UL approval: +
Signal voltage LOW: ≤ 2 V
Measurement: Switch, Continuous
3-A:
Inductive load: < 1 H
Connection type: Round connector M12 x 1, 5-pin
Housing design: With PMMA viewing window
Process pressure: -1 bar … 16 bar
Capacitive load: 100 nF
Lower signal level: 3.8 mA … 4 mA
Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
Interference resistance: EN 61000-6-2:2005
Max.probe load: 6 Nm
Protection class: III
Initialization time: ≤ 2 s
Output current: < 100 mA
MTTF: 194.3 a (EN ISO 13849-1)
Repeatability: ≤ 2 mm
Single- and continuous shock: EN 60068-2-27
Inactive area at process connector: 25 mm
Upper signal level: 20 mA … 20.5 mA
GOST approval: +
Temperature drift: < 0.1 mm/K
Resolution: < 2 mm
Accuracy of sensor element: ± 5 mm