SKU: MOC3ZA-KAZ33A6 Categories: , Brand:
  • Standstill monitoring by means of residual voltage measurement
  • 3 normally open and 1 normally closed positively guided safety contacts
  • 2 application diagnostic outputs for semiconductors
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 6044983
Contact type: Relay, positively guided
Mounting: 35 mm mounting rail according to EN 60715
Mechanical life: ≥ 50 1E 06 switching operations
Weight: 400 g
Power consumption: 10 VA
Contact configuration (safety contacts): 3 contacts NO, 1 contact NC
Performance level: PL e (EN ISO 13849-1)
Measurement inputs: L1/L2/L3
PFHd: 41 1E-09 (EN ISO 13849)
Protection class housing: IP 40
Safety integrity level: SIL3 (IEC 61508)
SILCL3 (EN 62061)
Nominal switching voltage: 250 V AC
Voltage threshold Uan: 20 mV … 400 mV, adjustable
Dimensions (W x H x D): 45 mm x 112 mm x 121 mm
Response time: 100 ms
Safety outputs: Normally open contact (13/14, 23/24, 33/34)
Vibration resistance: (EN 60068-2-6)
Category: Category 4 (EN ISO 13849-1)
Enclosure rating terminals: IP 20
Signal contacts 53/54 (normally open contact): 3 A/250 V AC G. P.
Standstill time ts: 0.2 s … 6 s, adjustable
Safe state in the event of a fault: The N/O is open; in other words, the safety-related enabling current paths are interrupted.
Hysteresis (for detection of running motor): 100 %
Switching capacity in accordance with AC 15: N/C: 2 A/230 V AC (EN 60947-5-1), N/O: 3 A/230 V AC (EN 60947-5-1)
Maximum switching frequency: 1,200 /h
Standstill: +
Measured/motor voltage: 690 V AC
Switching capacity in accordance with DC 13: 2 A/24 V DC (EN 60947-5-1)
Supply voltage semiconductor diagnostic outputs (A3/A4): 24 V DC (11 V DC … 30 V DC)
TM (mission time): 20 a (EN ISO 13849)
Contact service life at 230 V / 5 A (AC) cos φ = 0.5: ≥ 2 1E 05 switching operations
Stop category: 1 (EN 60204-1)
Positively guided N/C contacts: Normally closed contact (41/42)
Climate conditions according to: 25/060/04 (EN 60068-1)
For UL 508 applications only: 600 V AC
Semiconductor application diagnostics outputs (ON, ERR): Electrically isolated supply via A3/A4, Imax = 100 mA (short-circuit protected), ON for Release, ERR for Error