Home
» Sick » Sick PAC50-ACC

Sick PAC50-ACC

142.37

The price is not final. Please check with the manager!
SKU: PAC50-ACC Categories: , , Brand:
  • Electronic pressure switch for pneumatic applications
  • Large display shows system pressure, output states and set switching points
  • Three large function keys and intuitive menu navigation
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 1062953
Diagnostics output: Switching output 2 can be set as diagnostics output
Protection class III: +
Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M
Enclosure rating: IP 65 / IP 67 According to IEC 60529
Power consumption: Max. 40 mA at L+ = 24 VDC
Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
Zero point adjustment: Max. + 5 % of span
Medium: Dry compressed air
Setting accuracy of switching outputs: ≤ ± 0.2 % of span
Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180°
Rated temperature range: +10 °C … +60 °C
Pressure type: Gauge pressure
Initialization time: 300 ms
Process connection: PIF 4 mm + G ?
Measuring range: -1 bar … 0 bar
Accuracy: ≤ ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), ≤ ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
CULus certificate:
Vibration load: Max. 5 g (10 … 150 Hz), xyz, according to DIN EN 60068-2-6
Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V
Output signal: 2 x PNP/NPN/Push-Pull + 4 mA … 20 mA / 0 V … 10 V
Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2)
Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE
CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3
Non-repeatability: ≤ ± 0.2 % of span
RoHS certificate: +
Relative humidity: ≤ 90 %
Process temperature: 0 °C … +60 °C
Weight sensor: Ca. 40 g
CRUus certificate: +
Ambient temperature: 0 °C … +60 °C
Gauge pressure: -1 bar … 0 bar; -1 bar … +1 bar; 0 bar … +6 bar; 0 bar … +10 bar
Storage temperature: -20 °C … +80 °C