Part Number 1062983
Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output < 600 Ohm, Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA … 4 mA / 10 V … 0 V
Weight sensor: Ca. 40 g
Gauge pressure: -1 bar … 0 bar; -1 bar … +1 bar; 0 bar … +6 bar; 0 bar … +10 bar
Shock load: Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2)
Initialization time: 300 ms
Protection class III: +
Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M and L+, Protection class: III, Overvoltage protection: 32 V DC, Reverse polarity protection: L+ towards M
Accuracy: ≤ ± 1.5 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)), ≤ ± 2 % of span incl. temperature error (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
Storage temperature: -20 °C … +80 °C
Relative humidity: ≤ 90 %
Setting accuracy of switching outputs: ≤ ± 0.2 % of span
RoHS certificate: +
Display: Update: 1,000, 500, 200, 100 ms (adjustable), Pressure display: 4 digits, 16 segments, Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg, LCD with LED backlight (green/red), can be rotated electronically by 180°
Measuring range: 0 bar … 10 bar
Pressure type: Gauge pressure
Process connection: 2 x G ?
Output signal: 2 x PNP/NPN/Push-Pull
Power consumption: Max. 40 mA at L+ = 24 VDC
Non-repeatability: ≤ ± 0.2 % of span
CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3
Ambient temperature: 0 °C … +60 °C
Rated temperature range: +10 °C … +60 °C
Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE
Vibration load: Max. 5 g (10 … 150 Hz), xyz, according to DIN EN 60068-2-6
CULus certificate:
Enclosure rating: IP 65 / IP 67 According to IEC 60529
Zero point adjustment: Max. + 5 % of span
Diagnostics output: Switching output 2 can be set as diagnostics output
CRUus certificate: +
Medium: Dry compressed air
Process temperature: 0 °C … +60 °C