Home
» Sick » Sick PBSH-RB1X0SHGEED5A0Z

Sick PBSH-RB1X0SHGEED5A0Z

450.94

The price is not final. Please check with the manager!
SKU: PBSH-RB1X0SHGEED5A0Z Categories: , , Brand:
  • Hygienically-graded pressure switch with display for the food and beverage industry
  • Wetted parts are made from stainless steel 1.4435
  • Individually programmable switching outputs and analog output
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 6051859
Seal: Wetted parts: EPDM, Not wetted parts: EPDM
Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2)
Medium: Liquid and gaseous media
Accuracy: ≤ ± 1 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
Wetted parts: Stainless steel 1.4435 / 316L
CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3
Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C … 20 °C: 0.7 % of span / 10 K. In the temperature range 20 °C … 80 °C: 0.2 % of span / 10 K. typical TC of span: In the temperature range 0 °C … 80 °C: 0.1 % of the span / 10 K
Rated temperature range: 0 °C … +80 °C
Gauge pressure: 0 bar … 1 bar up to 0 bar … 25 bar
Absolute pressure: 0 bar … 1 bar up to 0 bar … 25 bar
Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M
Relative humidity: 45 % … 75 %
Setting accuracy of switching outputs: ≤ ± 0.5 % of span
Pressure type: Gauge pressure
Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: ≤ 1 % of span ± 1 digit
Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 °
Total current consumption: Max. 570 mA (incl. switching current)
Storage temperature: -20 °C … +80 °C
Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP
Compound pressure: -1 bar … 0 bar up to -1 bar … +24 bar
Maximum ohmic load RA: ≤ 0.5 k&;937;
Isolation voltage: 500 V DC
Enclosure rating: IP 65 / IP 67
Process temperature: -20 °C … +125 °C, +150 °C for max. 1 h
Ambient temperature: -20 °C … +80 °C
Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance)
Shock load: 50 g according to IEC 60068-2-27 (mechanical shock)
Protection class III: +
Housing material: Display window: PC, Plastic head: PC + ABS, Buttons: TPE-E, Lower body: stainless steel 304
Power consumption: Max. 70 mA
Long-term drift/one-year stability: ≤ ± 0.2 % of span according to IEC 61298-2
Overpressure safety: 2-fold
Zero point adjustment: Max. + 3 % of span
Output signal: 2 x PNP + 4 mA … 20 mA
Response time: 3 ms
Connection type: Round connector M12 x 1, 5-pin
Measuring range: 0 bar … 1 bar
Process connection: G 1 hygienic flush-mounted