Home
» Sick » Sick PBSH-RB6X0S54S0BMA0Z

Sick PBSH-RB6X0S54S0BMA0Z

447.40

The price is not final. Please check with the manager!
SKU: PBSH-RB6X0S54S0BMA0Z Categories: , , Brand:
  • Hygienically-graded pressure switch with display for the food and beverage industry
  • Wetted parts are made from stainless steel 1.4435
  • Individually programmable switching outputs and analog output
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 6051837
Rated temperature range: 0 °C … +80 °C
Shock load: 50 g according to IEC 60068-2-27 (mechanical shock)
EHEDG approval: +
Long-term drift/one-year stability: ≤ ± 0.2 % of span according to IEC 61298-2
Non-linearity: ≤ ± 0.5 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2)
Wetted parts: Stainless steel 1.4435 / 316L
Electrical safety: Short-circuit protection: QA, Q1, Q2 towards M, Protection class: III, Overvoltage protection: 40 V DC, Reverse polarity protection: L+ towards M
Enclosure rating: IP 65 / IP 67
Gauge pressure: 0 bar … 1 bar up to 0 bar … 25 bar
Storage temperature: -20 °C … +80 °C
Output signal: 1 x PNP + 4 mA … 20 mA
Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance)
Process temperature: -20 °C … +100 °C, +135 °C for max. 1 h
Isolation voltage: 500 V DC
Pressure type: Gauge pressure
Process connection: Conical coupling (DIN 11851) DN 40 with union nut
CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3
Seal: Without seal
Compound pressure: -1 bar … 0 bar up to -1 bar … +24 bar
Housing material: Display window: PC, Plastic head: PC + ABS, Buttons: TPE-E, Lower body: stainless steel 304
Medium: Liquid and gaseous media
Temperature coefficient in rated temperature range: Typical TC of zero: In the temperature range 0 °C … 20 °C: 0.7 % of span / 10 K. In the temperature range 20 °C … 80 °C: 0.2 % of span / 10 K. typical TC of span: In the temperature range 0 °C … 80 °C: 0.1 % of the span / 10 K
Accuracy: ≤ ± 1 % of span (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2))
Rotatable housing: Display against housing with electrical connection: 330 °, Housing against process connection: 320 °
Overpressure safety: 2-fold
Maximum ohmic load RA: ≤ 0.5 k&;937;
Ambient temperature: -20 °C … +80 °C
Zero point adjustment: Max. + 3 % of span
Measuring range: 0 bar … 6 bar
Connection type: Round connector M12 x 1, 4-pin
Response time: 3 ms
Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°, Update: 1,000, 500, 200, 100 ms (adjustable), Accuracy: ≤ 1 % of span ± 1 digit
Absolute pressure: 0 bar … 1 bar up to 0 bar … 25 bar
Total current consumption: Max. 320 mA (incl. switching current)
Power consumption: Max. 70 mA
Setting accuracy of switching outputs: ≤ ± 0.5 % of span
Relative humidity: 45 % … 75 %
Protection class III: +
Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP