Datasheet
Specification:
| Part Number | 6038791 |
| Supply voltage: | 10 V DC … 30 V DC |
| Protection class III: | + |
| Non-linearity: | <= -=”” 0=”” 2=”” of=”” span=”” best=”” fit=”” straight=”” line=”” bfsl=”” according=”” to=”” iec=”” 61298-2=”” td=””> |
| Pressure port: | Standard |
| Electrical safety: | Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M |
| Ambient temperature: | -20 °C … 80 °C |
| Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) |
| Weight sensor: | 200 g |
| CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 |
| Connection type: | M12 x 1, 4-pin, IP 67 |
| Output signal: | 4…20 mA |
| Shock load: | 1000 g according to IEC 60068-2-27 (mechanical shock) |
| Process temperature: | -30 °C … 100 °C |
| Response time (10 % … 90 %): | <= 1=”” ms=”” le=”” 10=”” at=”” medium=”” temperatures=”” below=”” -30=”” c=”” for=”” pressure=”” ranges=”” up=”” to=”” 25=”” bar=”” or=”” with=”” flush-mounted=”” membrane=”” td=””> |
| Storage temperature: | -40 °C … 100 °C |
| CE-conformity: | + |
| Enclosure rating: | IP 67 |
| Pressure type: | Compound pressure |
| Rated temperature range: | 0 °C … 80 °C |
| Temperature coefficient in rated temperature range: | Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤ 0.25 bar) |
| Non-repeatability: | <= -=”” 0=”” 1=”” of=”” span=”” td=””> |
| Measuring range: | -1 bar … 15 bar |
| Process connection: | G 1/4 female |
| Wetted parts: | Standard: Stainless steel |
| Accuracy: | <= -=”” 0=”” 5=”” of=”” span=”” td=””> |
| Seal: | Without seal |
| Vibration load: | 20 g according to IEC 60068-2-6 (vibration under resonance) |
| Housing material: | Stainless steel |
| Long-term drift/one-year stability: | <= -=”” 0=”” 2=”” of=”” span=”” at=”” reference=”” conditions=”” td=””> |