Datasheet
Specification:
| Part Number | 6039407 |
| Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) |
| Rated temperature: | 0 °C … 80 °C |
| Vibration load: | 15g per IEC 60068-2-6 (vibration under resonance) |
| CE-conformity: | + |
| Output signal: | 4…20 mA |
| Accuracy: | <= -=”” 0=”” 5=”” of=”” span=”” td=””> |
| Electrical safety: | Short-circuit protection: QA towards M, Overvoltage protection: 36 V DC, Reverse polarity protection: L+ towards M |
| Response time: | <= 10=”” ms=”” td=””> |
| Ambient temperature: | -20 °C … 80 °C |
| Process temperature: | -20 °C … 150 °C |
| Dielectric strength: | 500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions) |
| Enclosure rating: | IP 67 |
| Housing material: | Stainless steel 1.4571 |
| Supply voltage: | 11 V DC … 30 V DC |
| Process connection: | Tri-Clamp DN 1 ½” |
| Protection class III: | + |
| Measuring range: | 0 bar … 6 bar |
| Weight sensor: | ± 500 g |
| Non-linearity: | 0.2 % (Best Fit Straight Line (BFSL)) |
| Wetted parts: | Stainless steel 1.4435 |
| Pressure type: | Gauge pressure |
| Connection type: | Field housing IP 67 |