Datasheet
Specification:
| Part Number | 1045653 |
| Incremental encoder inputs: | – |
| Weight: | 3.3 kg |
| Response time: | 60 ms |
| Port properties: | Auto-negotiation Auto-crossover (MDIX) Auto-polarity 100Base-TX |
| Maximum warning field range: | 49 m |
| Hazardous area protection (horizontal): | + |
| Expanded measured data output (CMS): | – |
| Switch properties: | Filtering Data Base according to IEEE 802.1D 6 prioritization levels for IEEE 802.1Q – Network prioritization 64 KB SRAM memory for caching telegrams, managed in 768-byte segments Resource prioritization for network control and RTC2/3 frames Telegram extension based on “Cut-through” Port status (Disabled, Blocking, Forwarding) Support for non-real-time and real-time data transfer |
| Type: | Type 3 (IEC 61496) |
| Category: | Category 3 (EN ISO 13849) |
| Hazardous area protection (vertical): | + |
| Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm, configurable |
| PFHd: | 8.0 1E-08 (EN ISO 13849) |
| Access protection (vertical): | + |
| Safe SICK device communication via EFI/SDL: | – |
| Supply voltage: | 16.8 V DC, 24 V DC, 28.8 V DC |
| Static protective field switching: | + |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) |
| Number of simultaneously monitored protective fields: | 2 |
| Scan angle: | 190 ° |
| Device properties: | GSDML according to GSDML specification V2.25, PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2, PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4, Cycle time 4, 8, 16, 32 ms, etc. |
| Ambient operating temperature: | -10 °C … +50 °C |
| Interfaces for configuration and diagnostics using CDS: | TCP port 9000 and UDP port 30718 RS-232 |
| Number of monitoring cases: | 16 |
| Conformance: | Conformance Class B |
| Protection class: | III (VDE 0106, EN 60950) |
| Laser class: | 1 (21 CFR 1040.10 and 1040.11, DIN EN 60825:2001) |
| Performance level: | PL d (EN ISO 13849) |
| Measured data output: | + |
| TM (mission time): | 20 a (EN ISO 13849) |
| Functions that are not supported: | Multicast communication Supervisor AR MAC-pause mechanism in full duplex Back-pressure in half duplex Static learning Broadcast Storm Control |
| Diagnostics: | Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable Report system errors Cable diagnostics Neighborhood alerts Support for port statistics I&M support from I&M0 to I&M4 |
| Dimensions (W x H x D): | 155 mm x 185 mm x 160 mm |
| Integrated configuration memory: | + |
| Number of multiple samplings: | Configurable 2 … 16 |
| Number of field sets: | 8 |
| Distance measuring range: | 49 m |
| Configuration and diagnostics interface: | RS-232 |
| Protective field range: | 5.5 m |
| Type of field set: | Dual field sets |
| Topology support: | SNMP, MIB-2, LLDP nach IEEE 802.1AB MRP client support |
| Electrical connection: | Copper conductor (2 female connectors for RJ-45 push-pull plug), system plug with or without connecting cable |
| External device monitoring (EDM): | – |
| Enclosure rating: | IP 65 (EN 60529) |