Datasheet
| Module | Main module |
| Configuration method | Via rotary switch |
€0.00
Sick Safety controllers Flexi Classic / Main module
Sick Safety controllers Flexi Classic / Main module
| Module | Main module |
| Configuration method | Via rotary switch |
| Safety integrity level | SIL3 (IEC 61508) |
| Category | Category 4 (EN ISO 13849) |
| Performance level | PL e (EN ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) | 2.5 x 10-9 (EN ISO 13849) |
| TM (mission time) | 20 years (EN ISO 13849) |
| Restart interlock | Manual / automatic (configurable) |
| External device monitoring (EDM) | ✔ |
| AND operation | ✔ |
| Differentiation between man and material (muting) | ✔ |
| Global emergency stop | ✔ |
| Inputs |
4 safety inputs 2 switching inputs 2 inputs for the global emergency stop function |
| Outputs |
1 safety output 2 test outputs 1 diagnostic output 2 outputs for the global emergency stop function |
| Connection type | Plug-in spring terminals |
| Display elements | LEDs |
| Protection class | III (EN 61140) |
| Type of voltage supply | PELV or SELV 1) |
| Supply voltage VS | 24 V DC (19.2 V DC … 30 V DC) |
| Residual ripple | ≤ 10 % |
| Power consumption | ≤ 3 W (DC) |
| Switch-on time | ≤ 60 s |
| Internal power consumption | ≤ 3 W (DC) |