System part Sensor
Measurement principle HDDM+
Application Indoor
Light source Infrared (850 nm)
Laser class 1 (IEC 60825-1:2014, EN 60825-1:2014)
Aperture angle
Horizontal 270°
Scanning frequency 15 Hz
Angular resolution 0.33°
Scan field flatness ± 1.5°
Working range 0.05 m … 25 m (> 90% remission)
Safety-related working range 0.05 m … 5 m (At 5% remission)
Blind zone 0 m … 0.05 m
Scanning range
At 10% remission 8 m
  • Mechanics/electronics
    Connection type

    1 x “Ethernet” connection, 4-pin M12 female connector

    1 x connection “Power”, 12-pin, M12 male connector

    1 x Micro USB female connector, type B

    Supply voltage 9 V DC … 28 V DC
    Power consumption Typ. 4 W, 16 W with 4 max. loaded digital outputs
    Output current ≤ 100 mA
    Housing color Yellow
    Enclosure rating IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)
    Protection class III (IEC 61140:2016-1)
    Weight 250 g, without connecting cables
    Dimensions (L x W x H) 60 mm x 60 mm x 86 mm
  • Safety-related parameters
    Category B (EN ISO 13849-1:2015)
    Performance level PL b (EN ISO 13849-1:2015)
    Performance class SRS/SRSS B (IEC TS 62998-1:2019)
    TM (mission time) 20 years (EN ISO 13849-1:2015)
    Conformities EN ISO 13849-1:2015, ANSI/ITSDF B56.5:2012, IEC TS 62998-1:2019, EN ISO 13482:2014, EN ISO 13855:2010
    MTBF > 100 years
    MTTFd 100 years, at 25 °C ambient temperature (EN ISO 13849-1:2015)
  • Performance
    Response time

    1 scan, typ. 67 ms

    2 scans, ≤ 134 ms 1)

    Detectable object shape Almost any
    Systematic error ± 60 mm 2)
    Statistical error < 20 mm 2)
    Safety-related statistical error < 100 mm (4.4 σ)
    Integrated application Protective field evaluation with flexible fields, output of measurement data
    Protective field tolerance 100 mm, 0.66° (DIN CLC/TS 62046:2009, 5% remission)
    Number of field sets 16 field triples (48 protective fields)
    Simultaneous evaluation cases 3 simultaneous protective fields (per field set)