Description C4000 Fusion with extension connection on the receiver
Application Normal industrial environment
System part Pair
Resolution 20 mm
Scanning range 21 m
Protective field height 600 mm
Synchronization Optical synchronisation
Integrated laser alignment aid
  • Safety-related parameters
    Type Type 4 (IEC 61496-1)
    Safety integrity level

    SIL3 (IEC 61508)

    SILCL3 (EN 62061)

    Category Category 4 (EN ISO 13849)
    Performance level PL e (EN ISO 13849)
    PFHD (mean probability of a dangerous failure per hour) 15 * 10-9 (EN ISO 13849)
    TM (mission time) 20 years (EN ISO 13849)
    Safe state in the event of a fault At least one OSSD is in the OFF state.
  • Functions
    Functions Delivery status
    Protective operation
    Restart interlock Internal
    External device monitoring (EDM) Deactivated
    Beam coding Code 1
    Configurable scanning range
    Reduced resolution Deactivated
    Fixed blanking
    Dynamic blanking for object pattern recognition
    Self-teaching dynamic blanking for goods detection
    Self-teaching dynamic blanking for pallet detection
    Multiple sampling 2x evaluation
    Direction monitoring
    Virtual photoelectric switches
    Sensor gap monitoring
    Sequence monitoring
    Object entry monitoring
    Detection of geometrically even objects
    Emergency stop/bypass at the extension connection
    Safe SICK device communication via EFI
  • Functions in combination with UE402
    Bypass
    Operating mode switching
  • Interfaces
    System connection Hirschmann male connector M26, 12-pin
    Conductor cross section 0.75 mm²
    Permitted cable length ≤ 50 m
    Extension connection Hirschmann female connector M26, 12 pin
    Configuration connection Female connector M8, 4-pin
    Configuration method PC with CDS (Configuration and Diagnostic Software)
    Display elements 7-segment display
  • Electrical data
    Protection class III (IEC 61140)
    Supply voltage VS 24 V DC (19.2 V … 28.8 V) 1)
    Residual ripple ≤ 10 % 2)
    Output signal switching devices (OSSDs)
    Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored
    ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC … VS)
    OFF state, switching voltage LOW 2 V DC
    Current-carrying capacity per OSSD ≤ 500 mA