Home
» Sick » Sick EXE-06D6213A020

Sick EXE-06D6213A020

0.00

The price is not final. Please check with the manager!
SKU: EXE-06D6213A020 Categories: , Brand:

Sick Safety light curtains deTec / deTec4 Ex / Pair

Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Application Explosive areas
Ex-approvals

ATEX for gas: II 2 G Ex db IIB T6

ATEX for dust: II 2 D Ex tb IIIC T56°C Db IP6X

NFPA 70/NEC 500 Class I, Div. 1, Groups C and D

NFPA 70/NEC 500 Class II, Div. 1, Groups E, F and G

NFPA 70/NEC 500 Class III, Div. 1

System part Pair
Resolution 30 mm
Scanning range 25.2 m
Protective field height 600 mm
Response time

10 ms (Uncoded)

15 ms (code 1 or code 2)

Synchronization Optical synchronisation
Integrated laser alignment aid
Items supplied

Sender in explosion-proof enclosure with connecting cable, 30 m

Receiver in explosion-proof enclosure with connecting cable, 30 m

4 handles including screws

Test rod with diameter corresponding to the resolution of the safety light curtain

Safety instruction

Mounting instructions

Operating instructions on CD-ROM

  • Safety-related parameters
    Type Type 4 (IEC 61496-1)
    Safety integrity level

    SIL3 (IEC 61508)

    SILCL3 (IEC 62061)

    Category Category 4 (ISO 13849-1)
    Performance level PL e (ISO 13849-1)
    PFHD (mean probability of a dangerous failure per hour) 15.3 x 10-9
    TM (mission time) 20 years (ISO 13849-1)
    Safe state in the event of a fault At least one OSSD is in the OFF state.
  • Functions
    Protective operation
    Automatic calibration of the protective field width
    Beam coding
    Restart interlock
    External device monitoring (EDM)
  • Interfaces
    System connection Connecting cable, 30 m, flying lead, 8-wire
    Cable diameter 5.8 mm
    Conductor cross section 0.25 mm²
    Extension connection
    Configuration method DIP switch on system plug
    Display elements LEDs
    Display of the synchronization status of the upper and lower beams
    Application diagnostic output (ADO)
  • Electrical data
    Protection class III (IEC 61140)
    Supply voltage VS 24 V DC (19.2 V … 28.8 V)
    Ripple ≤ 10 %
    Power consumption typical 3.36 W (DC) / 1.38 W (DC)
    Output signal switching devices (OSSDs)
    Type of output 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 1)
    ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC … VS)
    OFF state, switching voltage LOW ≤ 2 V DC
    Current-carrying capacity per OSSD ≤ 500 mA
    Application diagnostic output (ADO)
    Type of output PNP semiconductor, short-circuit protected 1)
    Output voltage HIGH (active) ≥ Vs – 3 V
    Output voltage LOW (deactivated) High resistance
    Output current HIGH (active) ≤ 100 mA