Datasheet
| Applications | Evaluation unit |
| Compatible sensor types |
Safety sensors with OSSDs Safety sensors with test input Safety sensors with potential-free outputs Safety pressure mats |
€0.00
Sick Safety relays ReLy / Evaluation unit
Sick Safety relays ReLy / Evaluation unit
| Applications | Evaluation unit |
| Compatible sensor types |
Safety sensors with OSSDs Safety sensors with test input Safety sensors with potential-free outputs Safety pressure mats |
| Safety integrity level |
SIL3 (IEC 61508) SILCL3 (IEC 62061) |
| Category | Category 4 (ISO 13849-1) |
| Performance level | PL e (ISO 13849-1) |
| PFHD (mean probability of a dangerous failure per hour) | 1.5 × 10-9 |
| TM (mission time) | 20 years (ISO 13849-1) |
| Stop category | 0 (IEC 60204-1) |
| Sensor monitoring |
Discrepancy monitoring Sequence monitoring Cross-circuit detection |
| Restart interlock | ✔ |
| Reset |
Automatic Manual |
| External device monitoring (EDM) | ✔ |
| Connection type | Front connector with spring terminals |
| Inputs |
2 safety inputs 1 input for reset pushbutton or external device monitoring (EDM) |
| Outputs |
3 enabling current paths (safe) 2 application diagnostic outputs (not safe) 2 test pulse outputs (not safe) |
| Display elements | LEDs |
| Configuration method |
Hard wired DIP switch |
| Voltage supply | PELV or SELV |
| Supply voltage VS | 24 V DC (16.8 V … 30 V) |
| Residual ripple | ≤ 2.4 V |
| Power consumption | ≤ 2.5 W (DC) |
| Number | 2 | ||||||
|
|||||||
| Input current | 4 mA … 6 mA | ||||||
| Test pulse width | ≤ 1 ms | ||||||
| Test pulse rate | ≤ 10 Hz | ||||||
| Activation time tolerance between the two start buttons | ≤ 3 s | ||||||
| Number | 1 | ||||||
|
|||||||
| Input current | 4 mA … 6 mA | ||||||
| Response time | Depends on the configured sensor type, for details see operating instructions |
| Number | 3 |
| Type of output | N/O contacts, positively guided |
| Contact material | Silver alloy, gold flashed |
| Switching voltage |
10 V AC … 230 V AC 10 V DC … 230 V DC |
| Switching current | 10 mA … 6 A |
| Total current | 12 A |
| Mechanical life | 1 x 107 switching cycles |
| Overvoltage category | III (EN 60664-1) |
| Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
| Number | 2 | ||||||
| Type of output | Push-pull semiconductor output, short-circuit protected | ||||||
|
|||||||
| Input current (NPN) | ≤ 15 mA | ||||||
| Output current (PNP) | ≤ 120 mA | ||||||
| Number | 2 |
| Type of output | PNP semiconductors, short-circuit protected |
| Output voltage | ≥ Vs – 3 V |
| Test pulse width | Depends on the configured sensor type 1) |
| Test pulse interval | Depends on the configured sensor type, for details see operating instructions |