Datasheet
Specification:
| Part Number | 6043066 |
| Supply voltage: | 10 V DC … 35 V DC for variant with transmitter 4 mA … 20 mA |
| Signal output and maximum ohmic load RA: | 4 mA … 20 mA, 2-wire (RA ≤ (L+ – 10 V) / 0.028 A [Ohm]) |
| Shock resistance according to IEC 60751: | 500 g |
| Vibration resistance according to IEC 60751: | 3 g |
| Measuring current: | 0.3 mA … 1 mA |
| Protection class III: | + |
| Ambient temperature: | -40 °C … 85 °C |
| Storage and transport temperature: | -40 °C … 60 °C |
| Measuring range: | -50 °C … 150 °C |
| Process connection: | Compression fitting G 1/2 B, CrNi stainless steel ferrule |
| Sensor element: | Pt100 |
| Insertion length/diameter of probe: | 50 mm / 3 mm |
| Housing material: | Stainless steel 1.4571 |
| Accuracy of sensor element: | Class A according to IEC 60751 |
| Electrical connection/enclosure rating : | Cable gland M16 x 1.5, IP 65 |
| Wetted parts: | Stainless steel 1.4571 |
| Electrical safety: | Protection class: III, dielectric strength: 100 V, reverse polarity protection of variant with transmitter 4 mA … 20 mA: L+ towards M |
| Weight: | Ca. 155 g (depending on configuration) |
| Pressure resistance: | Max. 100 bar with supplied compression fitting with stainless steel ferrule |
| Transmitter linearity: | ≤ 0.1 % of span |
| CE-conformity: | 2004/108/EC, EN 61326-2-3 |
| Transmitter accuracy: | ≤ ± 0.1 % of span |