  • Pt100 element, accuracy class A according to IEC 60751
  • Measuring ranges -50 °C … 150 °C and -50 °C … 250 °C
  • Wetted parts made from corrosion resistant stainless steel 316L
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 6043238
Transmitter accuracy: ≤ ± 0.2 % of span
CE-conformity: 2004/108/EC, EN 61326-2-3
Housing material: Stainless steel 1.4571
Accuracy of sensor element: Class A according to IEC 60751
Sensor element: Pt100
Wetted parts: Stainless steel 1.4571
Protection class III: +
Transmitter linearity: ≤ 0.1 % of span
Insertion length/diameter of probe: 100 mm / 6 mm
Process connection: Thermowell G 1/2 B
Pressure resistance: Max. 220 bar
Electrical connection/enclosure rating : Plug M12 x 1, 4-pin, IP 67
Storage and transport temperature: -40 °C … 85 °C
Measuring current: 0.3 mA … 1 mA
Ambient temperature: -40 °C … 85 °C
Supply voltage: 10 V DC … 36 V DC for variant with transmitter 4 mA … 20 mA
Shock resistance according to IEC 60751: 500 g
Electrical safety: Protection class: III, dielectric strength: 500 V, reverse polarity protection: L+ towards M
Signal output and maximum ohmic load RA: 4 mA … 20 mA, 2-wire (RA <= (L+ - 9 V) / 0.023 A [Ohm])
Vibration resistance according to IEC 60751: 3 g
Weight: Ca. 145 g (depending on configuration)
Measuring range: -50 °C … 150 °C