  • Pt100 element, accuracy class A according to IEC 60751
  • Measuring ranges -50 °C … 150 °C and -50 °C … 250 °C
  • Wetted parts made from corrosion resistant stainless steel 316L
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Specification:

Part Number 6043323
Housing material: Stainless steel 1.4571
Pressure resistance: Max. 220 bar
Measuring current: 0.3 mA … 1 mA
Shock resistance according to IEC 60751: 500 g
Vibration resistance according to IEC 60751: 3 g
Ambient temperature: -40 °C … 85 °C
Storage and transport temperature: -40 °C … 85 °C
Wetted parts: Stainless steel 1.4571
Supply voltage: 10 V DC … 36 V DC for variant with transmitter 4 mA … 20 mA
Signal output and maximum ohmic load RA: 4 mA … 20 mA, 2-wire (RA <= (L+ - 9 V) / 0.023 A [Ohm])
Electrical connection/enclosure rating : Plug M12 x 1, 4-pin, IP 67
Weight: Ca. 145 g (depending on configuration)
CE-conformity: 2004/108/EC, EN 61326-2-3
Sensor element: Pt100
Accuracy of sensor element: Class A according to IEC 60751
Transmitter accuracy: ≤ ± 0.2 % of span
Measuring range: -50 °C … 250 °C
Electrical safety: Protection class: III, dielectric strength: 500 V, reverse polarity protection: L+ towards M
Insertion length/diameter of probe: 100 mm / 6 mm
Process connection: Thermowell G 1/2 B
Protection class III: +
Transmitter linearity: ≤ 0.1 % of span