Datasheet
Specification:
| Part Number | 6047626 |
| Process connection: | Conical coupling (DIN 11851) DN 40 with union nut |
| Accuracy of sensor element: | Class A according to IEC 60751 |
| Wetted parts: | stainless steel 1.4435 (316L), Ra ≤ 0.8 µm |
| Pressure resistance: | Max. 40 bar at room temperature |
| Output signal: | Pt100, 4-wire |
| Measuring current: | 0.3 mA … 1 mA |
| Electrical connection/enclosure rating : | Round connector M12 x 1, 4-pin / IP 68 and IP 69K |
| Measuring range: | -50 °C … 150 °C |
| Vibration resistance according to IEC 60751: | 3 g |
| Response time: | Response time t50: ≤ 4.7 s response time t90: ≤ 12.2 s |
| Housing material: | Stainless steel 1.4571 (316Ti) |
| Shock resistance: | According to IEC 60751 |
| Electrical safety: | Dielectric strength: 500 V AC Protection class: III |
| Insertion length/diameter of probe: | 100 mm / 6 mm |
| Sensor element: | Pt100 |
| Ambient temperature: | -40 °C … 85 °C |
| Transmitter accuracy: | ≤ ± 0.2 % of span |
| Relative humidity: | ≤ 95 % |
| Transmitter linearity: | ≤ ± 0.1 % of span |
| Protection class III: | + |
| Storage and transport temperature: | -40 °C … 85 °C |