Datasheet
Specification:
| Part Number | 6032472 |
| Enclosure rating terminals: | IP 20 (EN 60529) |
| TM (mission time): | 20 a (EN ISO 13849) |
| Number of muting sensors: | 0 … 2 |
| Type of voltage supply: | PELV or SELV |
| Voltage supply: | Via A1, A2 |
| Ripple: | ≤ 10 % |
| Restart interlock: | Manual / automatic (configurable) |
| Protection class housing: | IP 40 (EN 60529) |
| Performance level: | PL e (EN ISO 13849) |
| Dimensions (W x H x D): | 22.5 mm x 96.5 mm x 120.8 mm |
| PFHd: | 2.5 1E-09 (EN ISO 13849) |
| AND operation: | + |
| Supply voltage Vs: | 24 V DC (19.2 V DC … 30 V DC) |
| Vibration resistance: | 5 g RMS, 5 Hz … 500 Hz (EN 60068-2-64) |
| Number of outputs: | 2 dual-channel or 4 single-channel |
| Air humidity: | 15 % … 95 %, non-condensing |
| Differentiation between man and material (muting): | + |
| Power consumption: | 3 W (DC) |
| Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
| Climate conditions according to: | EN 61131-2 (55 °C ambient operating temperature, 95% rel. humidity) |
| Delay time (outputs Q3/Q4): | 0 s … 300 s |
| Connection type: | Plug-in screw-type terminals |
| OR operation: | + |
| Number of inputs: | 2 dual-channel or 4 single-channel |
| Eindrahtig oder feindrahtig (2x): | 0.14 mm? … 0.75 mm? |
| Storage temperature: | -25 °C … +70 °C |
| Protection class: | III (EN 61140) |
| Safe state in the event of a fault: | The safety-related semiconductor outputs are in the OFF state. |
| Finely stranded with ferrules (1x): | 0.25 mm? … 2.5 mm? |
| Finely stranded with ferrules (2x): | 0.25 mm? … 0.5 mm? |
| Eindrahtig oder feindrahtig (1x): | 0.14 mm? … 2.5 mm? |
| Ambient operating temperature: | -25 °C … +55 °C |
| Bypass: | + |
| External device monitoring (EDM): | + |
| Electromagnetic compatibility (EMC): | Class A (EN 61000-6-2, EN 55011) |
| Category: | Category 4 (EN ISO 13849) |
| Weight: | 180 g |