Datasheet
Product characteristics
| Output function | normally open |
|---|---|
| Sensing range [mm] | 12 |
| Housing | threaded type |
| Dimensions [mm] | M18 x 1 |
Application
| Special feature | Increased sensing range |
|---|
Electrical data
| Operating voltage [V] | 20…250 AC/DC |
|---|---|
| Protection class | I |
| Reverse polarity protection | no |
Outputs
| Output function | normally open |
|---|---|
| Max. voltage drop switching output DC [V] | 6 |
| Max. voltage drop switching output AC [V] | 6.5 |
| Minimum load current [mA] | 5 |
| Max. leakage current [mA] | 1 (250 V AC) / 0.8 (140 V AC) / 0.8 (24 V DC) |
| Permanent current rating of switching output AC [mA] | 250; (350 (…50 °C)) |
| Permanent current rating of switching output DC [mA] | 100 |
| Short-time current rating of switching output [mA] | 2200; (20 ms / 0,5 Hz) |
| Switching frequency AC [Hz] | 25 |
| Switching frequency DC [Hz] | 90 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range [mm] | 12 |
|---|---|
| Operating distance [mm] | 0…9.7 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.5 / copper: 0.4 |
|---|---|
| Hysteresis [% of Sr] | 3…15 |
Operating conditions
| Ambient temperature [°C] | -25…70 |
|---|---|
| Protection | IP 67 |
Tests / approvals
| EMC |
|
||||||||
|---|---|---|---|---|---|---|---|---|---|
| MTTF [years] | 616 | ||||||||
| UL approval |
|
Mechanical data
| Weight [g] | 63.2 |
|---|---|
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions [mm] | M18 x 1 |
| Thread designation | M18 x 1 |
| Materials | brass white bronze coated; PA; PBT |
Displays / operating elements
| Display |
|
|---|
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |
|---|
Accessories
| Items supplied |
|
|---|
Remarks
| Remarks |
|
|
|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection – plug
| Connector: 1 x 1/2″; coding: C |