Home
» Schneider Electric » Schneider LC1F4004

Schneider LC1F4004

0.00

The price is not final. Please check with the manager!

Schneider Electric contactor, TeSys F, 4P(4NO), AC-1, <=440V 500A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC

Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Main
Range TeSys
Product name TeSys F
Product or component type Contactor
Device short name LC1F
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
power pole contact composition 4 NO
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 500 A (at <40 °C) at <= 440 V AC AC-1
Complementary
[Uc] control circuit voltage 48…1000 V AC 40…400 Hz with LX1/LX9 coil
48…440 V DC with LX4 coil
100…250 V AC 50/60 Hz with LXE coil
100…380 V DC with LXE coil
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 500 A (at 40 °C)
Irms rated making capacity 4000 A AC conforming to IEC 60947-4-1
Rated breaking capacity 3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 3600 A 40 °C – 10 s
2400 A 40 °C – 30 s
1700 A 40 °C – 1 min
1200 A 40 °C – 3 min
1000 A 40 °C – 10 min
Associated fuse rating 400 A aM at <= 440 V
500 A gG at <= 440 V
Average impedance 0.26 mOhm – Ith 500 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole 65 W AC-1
Control circuit voltage limits Operational: 0.85…1.1 Uc AC 40…400 Hz with LX1/LX9 coil
Drop-out: 0.3…0.5 Uc AC 40…400 Hz with LX1/LX9 coil
Operational: 0.85…1.1 Uc DC with LX4 coil
Drop-out: 0.2…0.35 Uc DC with LX4 coil
Operational: 85…275 V AC 50/60 Hz with LXE coil
Drop-out: 0…60 V AC 50/60 Hz with LXE coil
Operational: 85…418 V DC with LXE coil
Drop-out: 0…45 V DC with LXE coil
Heat dissipation 14 W
2.2…5.5 W
Operating time 40…75 ms closing for with LX1/LX9 coil
100…170 ms opening for with LX1/LX9 coil
50…60 ms closing for with LX4 coil
45…60 ms opening for with LX4 coil
40…80 ms closing for with LXE coil
6…54 ms opening for with LXE coil
Mounting support Plate
Standards JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
Product certifications CB
ABS
DNV
RMRoS
LROS (Lloyds register of shipping)
BV
RINA
UL
CSA
UKCA
Connections – terminals Power circuit: bar 2 cable(s) – busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Tightening torque Power circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
Mechanical durability 10 Mcycles
Inrush power in VA 1000…1150 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
920…1140 VA (at 20 °C)with LX4 coil
360…470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
410…450 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA 12…18 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
4…7.5 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Maximum operating rate 2400 cyc/h 55 °C
Compatibility code LC1F
Environment
IP degree of protection IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C
Operating altitude 3000 m without derating
Mechanical robustness Vibrations contactor open: 1.5 Gn, 5…300 Hz
Vibrations contactor closed: 5 Gn, 5…300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height 206 mm
Width 261 mm
Depth 219 mm
Net weight 8 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 25.600 cm
Package 1 Width 25.400 cm
Package 1 Length 30.200 cm
Package 1 Weight 9.712 kg
Unit Type of Package 2 P06
Number of Units in Package 2 8
Package 2 Height 77.000 cm
Package 2 Width 80.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 89.620 kg
Contractual warranty
Warranty 18 months

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider LC1F4004