Schneider LC1F4004

0.00

The price is not final. Please check with the manager!

Schneider Electric contactor, TeSys F, 4P(4NO), AC-1, <=440V 500A with coil LX1/LX9 48…1000V AC 40/400Hz, LX4 48...440V DC, LXE 100...250V AC 50/60Hz or 100…380V DC

Ask a Question

Datasheet

Main
RangeTeSys
Product nameTeSys F
Product or component typeContactor
Device short nameLC1F
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
power pole contact composition4 NO
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current500 A (at <40 °C) at <= 440 V AC AC-1
Complementary
[Uc] control circuit voltage48…1000 V AC 40…400 Hz with LX1/LX9 coil
48…440 V DC with LX4 coil
100…250 V AC 50/60 Hz with LXE coil
100…380 V DC with LXE coil
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current500 A (at 40 °C)
Irms rated making capacity4000 A AC conforming to IEC 60947-4-1
Rated breaking capacity3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current3600 A 40 °C – 10 s
2400 A 40 °C – 30 s
1700 A 40 °C – 1 min
1200 A 40 °C – 3 min
1000 A 40 °C – 10 min
Associated fuse rating400 A aM at <= 440 V
500 A gG at <= 440 V
Average impedance0.26 mOhm – Ith 500 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole65 W AC-1
Control circuit voltage limitsOperational: 0.85…1.1 Uc AC 40…400 Hz with LX1/LX9 coil
Drop-out: 0.3…0.5 Uc AC 40…400 Hz with LX1/LX9 coil
Operational: 0.85…1.1 Uc DC with LX4 coil
Drop-out: 0.2…0.35 Uc DC with LX4 coil
Operational: 85…275 V AC 50/60 Hz with LXE coil
Drop-out: 0…60 V AC 50/60 Hz with LXE coil
Operational: 85…418 V DC with LXE coil
Drop-out: 0…45 V DC with LXE coil
Heat dissipation14 W
2.2…5.5 W
Operating time40…75 ms closing for with LX1/LX9 coil
100…170 ms opening for with LX1/LX9 coil
50…60 ms closing for with LX4 coil
45…60 ms opening for with LX4 coil
40…80 ms closing for with LXE coil
6…54 ms opening for with LXE coil
Mounting supportPlate
StandardsJIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
Product certificationsCB
ABS
DNV
RMRoS
LROS (Lloyds register of shipping)
BV
RINA
UL
CSA
UKCA
Connections – terminalsPower circuit: bar 2 cable(s) – busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
Tightening torquePower circuit: 35 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
Mechanical durability10 Mcycles
Inrush power in VA1000…1150 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
920…1140 VA (at 20 °C)with LX4 coil
360…470 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
410…450 VA (at 20 °C)with LXE coil
Hold-in power consumption in VA12…18 VA, 40…400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil
4…7.5 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
Maximum operating rate2400 cyc/h 55 °C
Compatibility codeLC1F
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…70 °C
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 1.5 Gn, 5…300 Hz
Vibrations contactor closed: 5 Gn, 5…300 Hz
Shocks contactor open: 6 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
Height206 mm
Width261 mm
Depth219 mm
Net weight8 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height25.600 cm
Package 1 Width25.400 cm
Package 1 Length30.200 cm
Package 1 Weight9.712 kg
Unit Type of Package 2P06
Number of Units in Package 28
Package 2 Height77.000 cm
Package 2 Width80.000 cm
Package 2 Length60.000 cm
Package 2 Weight89.620 kg
Contractual warranty
Warranty18 months