PROFIsafe IOL Device 8P IP67

  • Safety product in combination with IO-Link
  • Safe I/O module for PROFIsafe with safe inputs and outputs
  • Connection of safe mechanical contacts and OSSD sensors poss
Contact Sales
Delivery time 3–10 business days. Express available.
Returns 14 days return. New condition only.
Shipping EU, USA, worldwide.
DHL, DPD, UPS.

Datasheet

Application
Design only for operation with IO-Link master AL140x and Siemens PLC S7-1200 and S7-1500 (except Software Controller and Open Controller)
Application I/O modules for field applications
Electrical data
Operating voltage [V] 19.2…30.2 DC; (US ; to SELV/PELV)
Current consumption [mA] 67; (US)
Protection class III
Additional voltage supply [V] 19.2…30.2 DC; (UA)
Max. current consumption from additional supply [mA] 34; (UA)
Actuator supply UA
Max. current load total [A] 6
Current rating per port [A] 2
Inputs / outputs
Total number of inputs and outputs 12
Inputs
Total number of inputs 8
Switching level high [V] 11…30
Switching level low [V] -30…5
Digital inputs protected against short circuits yes
Outputs
Total number of outputs 4
Short-circuit proof yes
Interfaces
Communication interface IO-Link
Supported DeviceIDs
Type of operation DeviceID
Default 1312
IO-Link Device
Transmission type COM3 (230,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
SIO mode no
Operating conditions
Ambient temperature [°C] -25…60
Storage temperature [°C] -40…85
Max. relative air humidity [%] 75
Protection IP 65; IP 67
Tests / approvals
EMC
EN 61000-6-2
EN 61000-4-2 ESD 6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated 10 V/m
EN 61000-4-4 Burst 2 kV
EN 61000-4-5 Surge
EN 61000-4-6 HF conducted
Shock resistance
DIN EN 60068-2-27
Vibration resistance
DIN EN 60068-2-64 2009-04
DIN EN 60068-2-6 2008-10
Safety classification
Mission time TM [h] 175200
Mission time TM (additional indication)
20 years
Single channel
Complies with the requirements
ISO 13849-1 PL d
IEC 61508 SIL 2
IEC 62061 SIL 2
PFH [1/h] 1E-08
PFD [1/h] 1E-04
Dual channel
Complies with the requirements
ISO 13849-1 PL e
IEC 61508 SIL 3
IEC 62061 SIL 3
PFH [1/h] 1E-09
PFD [1/h] 1E-05
Mechanical data
Weight [g] 408.3
Materials housing: PA; socket: brass nickel-plated
Remarks
Remarks
Safety classification depends on parameterisation and wiring (see operating instructions).
Pack quantity 1 pcs.

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews