Product characteristics
| Measuring range of vibration [g] | -50…50 |
|---|---|
| Frequency range [Hz] | 1.5…12000 |
| Measuring principle | piezoelectric |
Application
| Special feature | Screened cable |
|---|---|
| Design | for connection to external diagnostic electronics VSE |
Electrical data
| Operating voltage [V] | 10…12 DC |
|---|---|
| Current consumption [mA] | 0.5…8 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Reverse polarity protection | yes |
Measuring/setting range
| Measuring range of vibration [g] | -50…50 |
|---|---|
| Frequency range [Hz] | 1.5…12000 |
| Measuring principle | piezoelectric |
| Noise density [mg] | 0.1 |
| Max. transverse sensitivity [%] | 5 |
| Minimum measuring time [s] | 2 |
| Number of measurement axes | 1 |
Accuracy / deviations
| Accuracy | ± 10 % |
|---|---|
| Measuring sensitivity | 100 mV/g |
Interfaces
| Communication interface | IEPE |
|---|
Operating conditions
| Ambient temperature [°C] | -50…150 |
|---|---|
| Storage temperature [°C] | -20…80 |
| Max. relative air humidity [%] | 80; (50 °C; 50 % non condensing) |
| Protection | IP 68; (water-proof up to 100 m 10 bar) |
Tests / approvals
| EMC |
|
||
|---|---|---|---|
| Shock resistance |
|
Mechanical data
| Weight [g] | 1892 |
|---|---|
| Type of mounting | M8 x 1,25 |
| Materials | housing: stainless steel |
| Tightening torque [Nm] | 8 |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Cable: 25 m, PTFE coated, blue, shielded |