Schneider Electric TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 400 A - coil 230 V AC

Ask a Question

Datasheet

Main
RangeTeSys
Range of productTeSys F
Product or component typeContactor
Device short nameLC1F
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-1
AC-3
AC-4
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz
<= 460 V DC
[Uc] control circuit voltage230 V AC 40…400 Hz
[Ie] rated operational current500 A (at <40 °C) at <= 440 V AC AC-1
400 A (at <55 °C) at <= 440 V AC AC-3
Complementary
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current500 A (at 40 °C)
Rated breaking capacity3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current3600 A 40 °C – 10 s
2400 A 40 °C – 30 s
1700 A 40 °C – 1 min
1200 A 40 °C – 3 min
1000 A 40 °C – 10 min
Associated fuse rating400 A aM at <= 440 V
500 A gG at <= 440 V
Average impedance0.26 mOhm – Ith 500 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole65 W AC-1
42 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Motor power kW75 kW at 400 V AC 50/60 Hz (AC-4)
200 kW at 380…400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
257 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660…690 V AC 50/60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
110 kW at 220…230 V AC 50/60 Hz (AC-3)
Control circuit voltage limitsOperational: 0.85…1.1 Uc 40…400 Hz (at 55 °C)
Drop-out: 0.3…0.5 Uc 40…400 Hz (at 55 °C)
Mechanical durability10 Mcycles
Inrush power in VA1075 VA, 40…400 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA15 VA, 40…400 Hz cos phi 0.9 (at 20 °C)
Maximum operating rate2400 cyc/h 55 °C
Operating time40…65 ms closing
100…170 ms opening
Connections – terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) – busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Power circuit: bolted connection
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 35 N.m
Mounting supportPlate
Heat dissipation14 W
motor power range110…220 kW at 480…500 V 3 phases
110…220 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
250…500 kW at 480…500 V 3 phases
Motor starter typeDirect on-line contactor
Contactor coil voltage230 V AC standard
StandardsEN 60947-1
EN 60947-4-1
IEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
Product certificationsABS
CSA
UL
BV
DNV
RMRoS
LROS (Lloyds register of shipping)
CB
RINA
UKCA
Compatibility codeLC1F
Control circuit typeAC at 40…400 Hz
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…70 °C
Height206 mm
Width213 mm
Depth219 mm
Operating altitude3000 m without derating
Net weight9.1 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height24.5 cm
Package 1 Width25.0 cm
Package 1 Length32.0 cm
Package 1 Weight9.137 kg
Unit Type of Package 2P06
Number of Units in Package 210
Package 2 Height75.0 cm
Package 2 Width80.0 cm
Package 2 Length60.0 cm
Package 2 Weight99.37 kg
Contractual warranty
Warranty18 months

Leave a Reply

Your email address will not be published. Required fields are marked *

Reviews

Reviews about the product Schneider LC1F400P7