Datasheet
Range of product | Altivar Process ATV600 |
---|---|
Product or component type | Variable speed drive |
Product specific application | Process and utilities |
Device short name | ATV660 |
Product destination | Synchronous motors Asynchronous motors |
Assembly style | In floor-standing enclosure compact version |
Provided equipment | Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor |
cable entry | Bottom |
Colour of enclosure | Light grey (RAL 7035) |
IP degree of protection | IP23 conforming to IEC 61800-5-1 |
Type of cooling | Forced convection |
[Us] rated supply voltage | 380…415 V – 10…6 % |
Supply frequency | 50/60 Hz +/-5 % |
Network number of phases | 3 phases |
Overvoltage category | III |
Asynchronous motor control profile | Variable torque standard Constant torque standard Optimized torque mode |
Synchronous motor control profile | Permanent magnet motor |
Output voltage | <= power supply voltage |
Permissible temporary current boost | 1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty) |
Nominal switching frequency | 2.5 kHz |
Switching frequency | 2…8 kHz adjustable with derating factor |
Speed drive output frequency | 0.1…500 Hz |
Motor power kW | 110 kW for normal duty 90 kW for heavy duty |
Continuous output current | 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty |
Maximum transient current | 232 A during 60 s per 10 min (normal duty) 260 A during 60 s per 10 min (heavy duty) |
Line current | 195 A at 400 V (normal duty) 164 A at 400 V (heavy duty) |
Apparent power | 135 kVA at 400 V (normal duty) 113 kVA at 400 V (heavy duty) |
Maximum THDI | <48 % full load conforming to IEC 61000-3-12 |
Short-circuit protection | Internal: 250.0 A aR fuse Upstream: 250.0 A gG fuse (normal duty) Upstream: 250.0 A gG fuse (heavy duty) |
Energy efficiency ratio | 0.98 |
Power dissipation in W | 2530 W, total (normal duty) 2010 W, total (heavy duty) 380 W, control part (normal duty) 300 W, control part (heavy duty) |
Volume of cooling air | 580 m3/h for power 140 m3/h for control |
Noise level | 69 dB conforming to 86/188/EEC – physical agents (noise) directive |
Prospective line Isc | 50 kA for 100 ms |
Electrical connection | Removable screw terminals, clamping capacity: 0.5…1.5 mm² for control M12 bar for main supply M12 bar for motor |
Motor recommanded cable cross section | 1 x (3 x 120 mm²) (normal duty) 2 x (3 x 50 mm²) (normal duty) 1 x (3 x 95 mm²) (heavy duty) |
Width | 400 mm |
Height | 2150 mm |
Depth | 664 mm |
Net weight | 300 kg |
number of preset speeds | 16 preset speeds |
communication port protocol | Modbus serial EtherNet/IP Modbus TCP |
Option card | Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module |
Safety function | STO (safe torque off), level SIL 3 for <= 100 ms |
EMC filter | Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 50 m Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 80 m |
Motor slip compensation | Automatic whatever the load Adjustable Not available in permanent magnet motor law Can be suppressed |
---|---|
Acceleration and deceleration ramps | S, U or customized Linear adjustable separately from 0.01 to 9000 s |
Braking to standstill | By DC injection |
Protection type | Motor: thermal protection Motor: safe torque off Motor: motor phase break Drive: thermal protection Drive: safe torque off Drive: overheating Drive: overcurrent (between output phases and earth) Drive: overload (output) Drive: short-circuit protection Drive: motor phase break Drive: overvoltage (DC bus) Drive: line supply overvoltage Drive: line supply undervoltage Drive: line supply phase loss Drive: overspeed Drive: break on the control circuit Drive: short-circuit protection with semi-conductor fuse (main supply) Drive: fan monitoring |
Frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
Connector type | RJ45 (on the control block) for Modbus serial RJ45 (on the control block) for Ethernet IP/Modbus TCP |
Physical interface | 2-wire RS 485 for Modbus serial |
Transmission frame | RTU for Modbus serial |
Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
Type of polarization | No impedance for Modbus serial |
Number of addresses | 1…247 for Modbus serial |
Method of access | Slave Modbus TCP |
Supply | External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
Local signalling | LCD display unit front door operation function, status and configuration |
Analogue input number | 3 |
Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits |
Discrete input number | 8 |
Discrete input type | DI1…DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
Input compatibility | DI1…DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 |
Discrete input logic | Positive logic (source) (DI1…DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1…DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
Analogue output number | 2 |
Analogue output type | Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits |
Sampling duration | 2 ms +/- 0.5 ms (DI1…DI4) – discrete input 5 ms +/- 1 ms (DI5, DI6) – discrete input 5 ms +/- 1 ms (AI1, AI2, AI3) – analog input 10 ms +/- 1 ms (AQ1, AQ2) – analog output |
Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
Relay output number | 3 |
Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Isolation | Between power and control terminals |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
---|---|
Operating position | Vertical +/- 10 degree |
Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
Vibration resistance | 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 |
Shock resistance | 4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3 |
Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
Ambient air temperature for operation | -10…0 °C without derating (with option enclosure heating) 0…40 °C without derating 40…50 °C with derating factor |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | < 1000 m without derating 1000…2000 m with current derating 1 % per 100 m 2000…3800 m with current derating 1 % per 100 m for TT earthing system 2000…3800 m with current derating 1 % per 100 m for TN earthing system 2000…3800 m with current derating 1 % per 100 m for IT earthing system 3800…4800 m with current derating 1 % per 100 m for TT earthing system 3800…4800 m with current derating 1 % per 100 m for TN earthing system |
Environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3 |
Standards | EN/IEC 60204-1 EN/IEC 61800-2 EN/IEC 61800-3 EN/IEC 61800-5-1 |
Product certifications | ATEX EAC C-Tick |
Product certifications | ATEX EAC C-Tick |
Marking | CE |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 215 cm |
Package 1 Width | 66.9 cm |
Package 1 Length | 40 cm |
Package 1 Weight | 340 kg |