Datasheet
Product characteristics
| Electrical design | PNP |
|---|---|
| Output function | 2 x normally open / normally closed; (selectable) |
| Communication interface | IO-Link |
| Housing | rectangular |
| Dimensions [mm] | 95 x 50 x 57 |
| Output function | 2 x normally open |
|---|
Application
| Operating principle | magnetic |
|---|---|
| Application | angle of rotation detection absolute |
Electrical data
| Operating voltage [V] | 10…30 DC |
|---|---|
| Current consumption [mA] | < 40 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time [ms] | 300 |
Inputs / outputs
| Number of inputs and outputs | Number of digital inputs: 1; Number of digital outputs: 2 |
|---|
Inputs
| Number of digital inputs | 1 |
|---|
Outputs
| Electrical design | PNP |
|---|---|
| Number of digital outputs | 2 |
| Output function | 2 x normally open / normally closed; (selectable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Max. current load per output [mA] | 100 |
| Short-circuit protection | yes |
| Overload protection | yes |
| Output function | 2 x normally open |
|---|---|
| Max. current load per output [mA] | 200 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Detection zone [°] | 360 |
|---|
Accuracy / deviations
| Accuracy [°] | ± 1 |
|---|---|
| Resolution [°] | 0.1 |
| Tolerance [°] | 0.1…15; (Default 10) |
| Hysteresis [°] | 0.1…5; (Default 3) |
| Temperature drift [°/K] | 0,02 |
| Repeatability [°] | 0,1 |
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | Smart Sensor: Device Identification; Device Diagnosis; Device Teach Channel; Binary Data Channel; Process Data Variable; Blob; Measurement Data Channel | ||||
| SIO mode | yes | ||||
| Required master port type | A | ||||
| Min. process cycle time [ms] | 4 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°C] | -25…70 |
|---|---|
| Protection | IP 65; IP 67; (Target puck area dust-protected) |
Tests / approvals
| EMC |
|
||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Vibration resistance |
|
||||||||||
| Shock resistance |
|
||||||||||
| MTTF [years] | 363 | ||||||||||
| UL approval |
|
Mechanical data
| Weight [g] | 192 |
|---|---|
| Housing | rectangular |
| Dimensions [mm] | 95 x 50 x 57 |
| Materials | PA |
| Tightening torque [Nm] | 3 |
Displays / operating elements
| Display |
|
|---|
Accessories
| Items supplied |
|
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection – solenoid valve
| Connector: 1 x M12; coding: A; Moulded body: stainless steel |
Other data
Inputs
| Operating mode | 12 V | 24 V |
| switching level high | 6…30 V | 15…30 V |
| switching level low | 0…2 V | 0…5 V |