Home
» IFM Electronic » Sensors » Flow sensors » IFM SD6800 industrial gas counter

IFM SD6800 industrial gas counter

0.00

The price is not final. Please check with the manager!
SKU: SD6800 Categories: , , Tag:

SDR12DGXFRKG/US-100

  • Precise measurement of flow, consumption, pressure and medium temperature
  • High accuracy, repeatability and measurement dynamics
  • For the detection of helium
  • Red/gre
Contact Sales

Datasheet

Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Process connection threaded connection R 1/2 DN15
Pressure monitoring
Measuring range [bar] -1…16
Application
Application for industrial applications
Media helium
Medium temperature [°C] -10…60
Min. bursting pressure [bar] 64
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
MAWP (for applications according to CRN) [bar] 9.7
Electrical data
Operating voltage [V] 18…30 DC; (to SELV/PELV)
Current consumption [mA] < 80
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Inputs counter reset
Outputs
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V] 2.5
Permanent current rating of switching output DC [mA] 150; (per output)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
1.5…166.5 l/min 0.1…13.3 m/s 0.1…10 m³/h
Display range
1.5…200 l/min 0.1…16 m/s 0.1…12 m³/h
Resolution
1 l/min 0.1 m/s 0.05 m³/h
Set point SP
2.7…166.7 l/min 0.2…13.3 m/s 0.16…10 m³/h
Reset point rP
1.8…165.8 l/min 0.1…13.2 m/s 0.11…9.95 m³/h
Analogue start point ASP
0…133.3 l/min 0…10.6 m/s 0…8 m³/h
Analogue end point AEP
33.4…166.7 l/min 2.7…13.3 m/s 2…10 m³/h
Low flow cut-off LFC
1.3…1.7 l/min 0.1 m/s 0.08…0.1 m³/h
In steps of
1 l/min 0.1 m/s 0.01 m³/h
Pressure monitoring
Measuring range [bar] -1…16
Display range [bar] -1…20
Resolution [bar] 0.05
Set point SP [bar] -0.92…16
Reset point rP [bar] -1…15.92
Analogue start point [bar] -1…12.8
Analogue end point [bar] 2.2…16
In steps of [bar] 0.01
Volumetric flow quantity monitoring
Measuring range
0…100000000 m³ 0…353146667.2 scf
Display range
0…100000000 m³ 0…353146667.2 scf
Set point SP
0.001…10000000 m³ 0.05…353146667.2 scf
Pulse value
0.001…10000000 m³ 0.05…353146667.2 scf
In steps of
0.0001 m³ 0.005 scf
Pulse length [s] 0.002…2
Temperature monitoring
Measuring range
-10…60 °C 14…140 °F
Display range
-24…74 °C -11.2…165.2 °F
Resolution
0.2 °C 0.5 °F
Set point SP
-9.7…60 °C 14.6…140 °F
Reset point rP
-10…59.7 °C 14…139.4 °F
Analogue start point
-10…46 °C 14…114.8 °F
Analogue end point
4…60 °C 39.2…140 °F
In steps of
0.1 °C 0.1 °F
Accuracy / deviations
Temperature coefficient [1/K] ± 0,07 % MW
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW); at medium temperature 23 °C
Repeatability 0,8 % MW + 0,2 % MEW
Pressure monitoring
Repeatability [% of the final value] ± 0,2
Characteristics deviation [% of the final value] < ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K] ± 0,15
Greatest TEMPCO of the zero point [% MEW / 10 K] ± 0,25
Temperature monitoring
Accuracy [K] ± 0,5; (medium flow in the limit area of the flow measurement range)
Response times
Response time [s] 0.1; (dAP = 0)
Damping process value dAP [s] 0…5
Pressure monitoring
Response time [s] 0.05
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 0,5
Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO mode yes
Required master port type A
Process data analogue 8
Process data binary 2
Min. process cycle time [ms] 7.2
Supported DeviceIDs
Type of operation DeviceID
Default 1302
Operating conditions
Ambient temperature [°C] 0…60
Storage temperature [°C] -20…85
Max. relative air humidity [%] 90
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
CPA approval
model number 003TG
accuracy class
maximum allowable error ± 7 % FS
Q (min) 0,1 m³/h (He)
Q (t)
Q (max) 10 m³/h (He)
Vibration resistance
DIN EN 68000-2-6 5 g (10…2000 Hz)
MTTF [years] 180
UL approval
UL Approval no. I012
File number UL E174189
Pressure Equipment Directive Sound engineering practice; can be used for stable gases fluid group 2
Mechanical data
Weight [g] 715.7
Materials PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts) stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connection threaded connection R 1/2 DN15
Displays / operating elements
Display
colour display 1,44″, 128 x 128 pixels
2 x LED, yellow
Remarks
Remarks
MW = measured value
MEW = Final value of the measuring range
Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity
For information about installation and operation please see the operating instructions.
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A